• Tandem or private line automatic ringdown mode with
D3 or D4 signaling.
• Transmit and receive gain/attenuation adjustable in
0.1 dB increments.
• Transmit input range of -4.5 to 1.8 dBm.
• Receive output range of -6.3 to 0.0 dBm.
• Complies with AT&T Publications 43801, 41008,
41009, and Bellcore GR-1089-CORE requirements
for Type 1 Equipment.
• Supports Calling Number Delivery and other common
TM
(CLASS
) service offerings according to TR TSY
000030 section 3.3.1.1.

2. INSTALLATION

After unpacking the unit, immediately inspect it for
possible shipping damage. If damage is discovered, file
a claim immediately with the carrier and then contact
ADTRAN customer service (see section 6, Warranty and
Customer Service ).
The 2FXS/DPO PM plugs directly into an ADTRAN ACT
2300/1900 or standard D4 channel bank. No installation
wiring is required. To install, grasp the 2FXS/DPO PM by
the faceplate and insert it into the backplane connector
until firmly seated.
Provisioning Options
Most options on the 2FXS/DPO are provisionable either
manually, using internal slide switches, or electronically
using a menu-driven program called EASYMENU. The
trunk processing options are found on internal slide
Switch 7 (SW7) and can only be provisioned manually.
Manual provisioning should be completed before
the 2FXS/DPO is inserted into the channel
bank.
Electronic provisioning should be
completed following installation.
Manual Provisioning
Internal slide switches SW1,2, 3, 4, and SW7 are used to
manually provision and set the operational modes and
options of the unit. Figure 1 displays switch locations.
Slide switches SW1 and SW2 are used to set, receive, and
transmit attenuation. Table A displays the available options.
Slide switches SW3-1, 2, 3, 4, and SW3-5 are used to
provision the desired operation mode of the unit.
Slide switch SW4 is used to provision the trunk processing
(SD), dial pulse correction (DPC), loop or ground start (GS),
PLAR mode (PD3), tandem battery mode (TRB), tandem
start mode (TWS), dial tone (DTG), and ringback tone
(RTG).
Slide switch SW7 is used to provision the trunk processing
options: make busy lead (1G), make busy closure (L), and
busy trunk sleeve (S). Table B summarizes the option
settings for SW3, SW4, and SW7.
2

Table A. SW1 (Receive) and SW2 (Transmit)

Add Attenuation
Note 1:
Note 2:
Note 3:

Table B. SW3, SW4, and SW5 Option Settings

Function
Impedance
TNDM Mode
PLAR Mode
FXS Mode
DPO Mode
Ringback Tone
Dial Tone
Tandem Mode
Signaling
Tandem Mode
Battery
PLAR Mode
Trunk Type
Start Mode
Dial Pulse
Correction
Busy Trunk
During CFA
Make Busy
Lead 1 Ground
Make Busy
Closure
Busy Trunk Sleeve
Option during CFA
Section 61109403L2-5, Issue 3
Attenuation Options.
Function
Selection/Setting
Amount in dB
0.1 dB
0.2 dB
0.4 dB
0.8 dB
1.6 dB
3.2 dB
Factory default setting for all switches is "off."
Multiple switch activation causes a cumulative effect
on the amount of attenuation added.
The largest transmit attenuation value in 2-Wire
mode is 6.3 dB.
Switch
Selection
Operational Mode
SW3-1
900 ohms
(Z900)
600 ohms
SW3-2
Enabled
(TNDM)
Disabled
SW3-3
Enabled
(PLAR)
Disabled
SW3-4
Enabled
(FXS)
Disabled
SW3-5
Enabled
(DPO)
Disabled
General Parameters
SW4-1
Enabled
(RTG)
Disabled
SW4-2
Enabled
(DTG)
Disabled
SW4-3
(TWS)
Immediate
SW4-4
Reverse
(TRB)
Normal
SW4-5
(PD3)
SW4-6
Group
(GS)
SW4-7
Enabled
(DPC)
Disabled
SW4-8
Enabled
(SD)
Disabled
Trunk Processing
SW7-2
Enabled
(1G)
Disabled
SW7-3
Enabled
(L)
Disabled
SW7-4
Enabled
(S)
Disabled
Activate
Switch to
"On" Position
SW1,2 - 6
SW1,2 - 5
SW1,2 - 4
SW1,2 - 3
SW1,2 - 2
SW1,2 - 1
Setting
ON
OFF
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Wink
Off
On
Off
On
D3
D4
Off
On
Loop
Off
On
Off
On
Off
On
Off
On
Off
On
Off
61109.403L2-5C