Specifications - Victron energy SmartSolar MPPT 100/30 Manual

Charge controller
Hide thumbs Also See for SmartSolar MPPT 100/30:
Table of Contents

Advertisement

5. Specifications

SmartSolar Charge Controller
Battery voltage
Rated charge current
Nominal PV power, 12V 1a,b)
Nominal PV power, 24V 1a,b)
Maximum PV open circuit voltage
Max. PV short circuit current 2)
Maximum efficiency
Self-consumption
Charge voltage 'absorption'
Charge voltage 'equalization' 3)
Charge voltage 'float'
Charge algorithm
Temperature compensation
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication port
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
STANDARDS
Safety
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher sort circuit current may damage the controller in case of reverse
polarity connection of the PV array.
3) Default setting: OFF
12
MPPT 100/30
12/24V Auto Select
30A
440W
880W
100V
35A
98%
Default setting: 14,4V / 28,8V (adjustable)
Default setting: 16,2V / 28,8V (adjustable)
Default setting: 13,8V / 27,6V (adjustable)
multi-stage adaptive (eight preprogrammed
algorithms) or user defined algrithm
-16 mV / °C resp. -32 mV / °C
Battery reverse polarity (fuse, not user
Output short circuit, Over temperature
-30 to +60°C (full rated output up to 40°C)
95%, non-condensing
5000m (full rated output up to 2000m)
Indoor type 1, unconditioned
Bluetooth and VE.Direct
See the data communication white paper on
ENCLOSURE
IP43 (electronic components),
IP22 (connection area)
130 x 186 x 70 mm
EN/IEC 62109-1, UL 1741, CSA C22.2
MPPT 100/50
50A
700W
1400W
100V
60A
98%
10 mA
accessible)
PD3
our website
Blue (RAL 5012)
16 mm² / AWG6
1,3 kg

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartsolar mppt 100/50