Download Print this page
ACP RMS10TSA Technical Information

ACP RMS10TSA Technical Information

Commercial microwave

Advertisement

Quick Links

Commercial Microwave
120V, 60 Hz Models
RMS10TSA
MMS10TSA
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
Service should only be performed by a Qualified Service Technician
To avoid the risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing.
Power Source
Voltage AC
Amperage (Single Unit)
Frequency
Single Phase, 3 wire grounded
Receptacle
Plug
Power Output
Nominal microwave energy (IEC705)
Minimum temperature rise (∆T)
Operating Frequency
Power Consumption
Cook Condition Microwave
Dimensions
Cabinet
Width
Height
Depth
Oven Interior
Width
Height
Depth
Weight
Crated
Uncrated
May 2019
©2019 ACP, Inc.
Technical Information
P2006701M
P2006705M
Models
RMS10DSA
P2006702M
MMS10DSA
*MS10DSA / *MS10TSA
120 VAC
15 A
60 Hz
X
5-15R
5-15P
1000 Watts
10º F / 5º C
2450 MHz
1550 Watts
512 (20 1/8")
310 (12 1/4")
403 (15 7/8")
330 (13")
197 (7 3/4")
330 (13")
16.8kg (37 lbs)
13.6 kg. (30 lbs)
P2006706M
16500067
Rev 2

Advertisement

loading

Summary of Contents for ACP RMS10TSA

  • Page 1 512 (20 1/8”) Width 310 (12 1/4”) Height 403 (15 7/8”) Depth Oven Interior Width 330 (13") Height 197 (7 3/4") Depth 330 (13") Weight Crated 16.8kg (37 lbs) Uncrated 13.6 kg. (30 lbs) May 2019 16500067 ©2019 ACP, Inc. Rev 2...
  • Page 2: Component Testing Procedures

    Fuse Block Power In terminals ........120vac 120vac Filter Assembly Power Out terminals ........If no power in, check power outlet If no power out, check fuse Fuse…………………………………………… Rated 20A Fuse 250vac May 2019 16500067 ©2019 ACP, Inc. Rev 2...
  • Page 3: Service Mode

    1) Open door and Press/Hold Pad #3 for 5 seconds or until “SErV” is Displayed 2) Press Pad #1 to display Magnetron Hours in 100’s. 3) Press Pad #3 to display Door Cycles in 100’s May 2019 16500067 ©2019 ACP, Inc. Rev 2...
  • Page 4 17 ....1700 25 ....2500 9.5 .... 1700 13.5..2500 18 ....1800 27 ....2700 10 ..... 1800 15.... 2700 19 ....1900 30 ....3000 10.5 ..1900 16.5..3000 May 2019 16500067 ©2019 ACP, Inc. Rev 2...
  • Page 5: Wiring Schematic & Diagram

    Wiring Schematic & Diagram To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor before servicing, unless testing requires power. May 2019 16500067 ©2019 ACP, Inc. Rev 2...
  • Page 6 Electronic Control Operation So…how do I use it? Interrupting Operation (Pause Mode) While the oven is operating, press STOP/RESET key to interrupt operation. Display shows remaining cooking time. Close door and press START key ( B) resume oven operation. Canceling Mistakes If oven is not cooking, press STOP/RESET key to clear display.
  • Page 7: Electronic Control Operation

    Electronic Control Operation Programming Mode PROGRAMMING EXAMPLE: This mode allows the user to assign cook times, power levels, and stage cooking to To save a cook setting of 1 minute the Number Keys. and 25 seconds at 70% power on Number Key “3”.
  • Page 8 Electronic Control Operation On-the-Fly Cooking CHANGING USER OPTION EXAMPLE: On-the-Fly Cooking allows the user to start another cook cycle while the oven is operating or paused. To set the key beep volume to high. Open oven door and press Number Note: User Option OP:51 must be enabled for use of On-the-Fly cooking.

This manual is also suitable for:

Mms10tsaRms10dsaMms10dsaP2006701mP2006705mP2006702m ... Show all