Storing The Machine - Stihl MS 194 C Instruction Manual

Chain saw
Table of Contents

Advertisement

Available languages

Available languages

Checking the spark plug
Clean the spark plug if it is dirty
N
Check the electrode gap (A) and
N
readjust if necessary – see
"Specifications"
Use only resistor type spark plugs of
N
the approved range. See the
chapter "Specifications" in this
instruction manual
Correct the problems that have caused
fouling of the spark plug:
too much oil in fuel mix;
dirty air filter; or
unfavorable running conditions, e.g.
operating at part throttle.
MS 194 C
A
WARNING
To reduce the risk of fire and burn injury,
use only spark plugs authorized by
STIHL. Always press the spark plug
boot (1) firmly and securely onto the
spark plug terminal (2).
Do not use a spark plug with a
detachable SAE adapter terminal (3).
Arcing may occur that could ignite
combustible fumes and cause a fire.
This can result in serious injuries or
damage to property.
Only use resistor type spark plugs
N
with solid, non-threaded terminals
Installing the Spark Plug
Screw the spark plug into the
N
cylinder.
Connect the spark plug boot (press
N
it down firmly).
1
3
2

Storing the Machine

For periods of 3 months or longer
Drain and clean the fuel tank in a
N
well ventilated area.
Dispose of fuel properly in
N
accordance with local
environmental requirements.
Run the engine until the carburetor
N
is dry – this helps prevent the
carburetor diaphragms sticking
together.
Remove the saw chain and guide
N
bar, clean them and spray with
corrosion inhibiting oil.
Thoroughly clean the machine – pay
N
special attention to the cylinder fins
and air filter.
If you use a biological chain and bar
N
lubricant, e.g. STIHL BioPlus,
completely fill the chain oil tank.
Store the machine in a dry, high or
N
locked location, out of the reach of
children and other unauthorized
persons.
English
45

Hide quick links: