PSEN cs2.13p ATEX
Environmental data
Storage temperature
In accordance with the standard
Climatic suitability
In accordance with the standard
Humidity
EMC
Vibration
In accordance with the standard
Frequency
Amplitude
Shock stress
In accordance with the standard
Acceleration
Duration
Airgap creepage
Overvoltage category
Pollution degree
Rated insulation voltage
Rated impulse withstand voltage
Protection type
Housing
Mechanical data
Actuator 1
Operating distances
Assured operating distance Sao
Typical operating distance So
Assured release distance Sar
Typical release distance Sr
Repetition accuracy switching distances
Change of operating distance with temperature
changes
Typ. Hysteresis
Min. distance between safety switches
Sensor flush installation in accordance with EN
60947-5-2
Connection type
Material
Top
Max. torque setting for fixing screws
Dimensions
Height
Width
Depth
Operating Manual PSEN cs2.13p ATEX
21133-2EN-1
EN 60068-2-1/-2
EN 60068-2-78
93 % r. h. at 40 °C
EN 60947-5-3
EN 60947-5-2
10 - 55 Hz
1 mm
EN 60947-5-2
30g
11 ms
III
3
75 V
1 kV
IP67
PSEN cs2.1
15 mm
21 mm
40 mm
32 mm
10 %
+-0,01mm/°C
3 mm
400 mm
Yes, follow installation guidelines
M12, 8-pin male connector
PBT
1 Nm
75 mm
40 mm
40 mm
45