Each error code is indicated by three short flashes of the "Input" or "Safety Gate" LED.
After a longer pause, the LED will then flash at one second intervals. The number of LED
flashes corresponds to a digit in the error code. The error code can consist of up to 3 digits.
The digits are separated by a longer period without flashing. The entire sequence is con-
stantly repeated.
Number of flashes
Decimal error code
Example:
Error code 1,4,1:
Flash frequency of the "Safety Gate" or "Input" LED
Meaning of flash frequency:
Flash frequency
I
3 times, short
II
Once, for one second each
III
4 times, for one second each
IV
Once, for one second each
V
3 times, short
Table of error codes
Error code
Decimal
1.4.1
1.12
1.13
14
15
Other flashing codes signal an internal error. Remedy: Change device.
Operating Manual PSEN cs2.13p ATEX
21133-2EN-1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0
II
I
Number of flashes
3x short – 1x long – 4x
long – 1x long – 3x short
3x short – 1x long – 12x
long – 3x short
3x short – 1x long – 12x
long – 3x short
3x short – 14x long – 3x
short
3x short – 15x long – 3x
short
III
IV
V
Meaning
Code for error message
Code for 1st digit
Code for 2nd digit
Code for 3rd digit
Code for error message repeated
Description
Wiring error
Wiring error
Wiring error
Wiring error
Wiring error
Remedy
Rectify wiring error
Rectify wiring error
Rectify wiring error
Rectify wiring error
Rectify wiring error