PSEN cs2.13p ATEX
PNOZmulti for safety gate monitoring
}
Configure the switch in the PNOZmulti Configurator with switch type 3.
PSS for safety gate monitoring with standard function block SB064, SB066 or
}
FS_Safety Gate
PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate
}
The correct connection to the respective evaluation device is described in the instructions
for the evaluation device. Make sure that the connection is made in accordance with the
specifications in the instructions for the selected evaluation device.
The connections to two evaluation devices are shown on the following pages, by way of ex-
ample:
PNOZ s3 and
}
PNOZmulti
}
PNOZ s3
PNOZmulti
Operating Manual PSEN cs2.13p ATEX
21133-2EN-1
PNOZ s3
A1
A2
S12
S22
PNOZmulti
A1
A2
I0
I1
I2
PSENcode
A1
2
7
A2
5
Y32
8
n.c.
6
S11
1
S21
3
12
4
22
PSENcode
2
A1
7
A2
n.c.
8
6
S11
1
S21
grün
3
12
gelb
4
22
grau
5
Y32
38