ACTIVATING THE COMPRESSOR SYSTEM
(See Figure B.14 and B.15)
1. The compressor can be activated in low or high idle.
2. Close the ball valve, Item 47, as shown in the Figure B.14.
FIGURE B.14
3. Press the power switch, Item 50, to the compressor ON
4. Watch the pressure gage, Item 51, for an increase in pressure
to approximately 150-160 psi, depending on the idle speed
selected.
5. The hour meter, Item 48, will activate and show the total
hours on the compressor system.
6. The amber fault light, Item 49, should not be illuminated when
the system is functioning normally.
• If the compressor system does not come on and/or the fault
light is illuminated, turn off the compressor power switch,
then turn off the machine (RUN/STOP to OFF) and go to the
"TROUBLE SHOOTING" section to locate the cause of the
problem.
7. The compressor system is ready to use after warming up for
about one minute.
8. Connect up to the ball valve (3/4 NPT )and open fully to use
the system air
DEACTIVATING THE COMPRESSOR SYSTEM
1. Close the ball valve, Item 47, as shown in the Figure B.14.
2. Press the power switch, Item 50, to the "OFF" position, which
3. Watch the pressure gage, Item 51, for a decrease in pressure
to approximately to 0 psi. This should take place in one
minute or less.
47
C PUMP S YSTEM
50
B-8
OPERATION
FIGURE B.15
COMPRESSOR SYSTEM
48
49