Siemens SIMATIC NET RUGGEDCOM RS930L Installation Manual page 44

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS930L:
Table of Contents

Advertisement

61000-4-16
61000-4-17
61000-4-29
IEC 60255-5
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RS930L meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports. Class 1 allows for temporary communica-
tion loss, while Class 2 requires error-free and interrupted communications.
Fast Transient
RUGGEDCOM RS930L
Installation Manual, 02/2020, C79000-G8976-1034-06
Test
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
IEC
Voltage Dips and Interrupts
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Oscillatory
HV Impulse
6.2 EMC and Environmental Type Tests
Description
Signal Ports
DC Pow-
er Ports
DC Pow-
er Ports
DC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Signal Ports
DC Pow-
er Ports
AC Pow-
er Ports
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
Test Levels
1 kV Differential
Mode @ 1 MHz
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
15%
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Failsafe Relay Output)
2 kV
2 kV
5 kV (Failsafe Relay Output)
5 kV
5 kV
Test Levels
± 8 kV
± 15 kV
35 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV Common Mode @ 1 MHz
2.5 kV Common and Dif-
ferential Mode @ 1 MHz
2.5 kV Common and Dif-
ferential Mode @ 1 MHz
5 kV (Failsafe Relay)
5 kV
Certification
Severi-
ty Levels
4
4
3
 
 
 
 
 
 
 
35

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC NET RUGGEDCOM RS930L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents