2.
RUGGEDCOM RS930L
Installation Manual, 02/2020, C79000-G8976-1034-06
Connect the positive wire from the power source to the positive/live (+/L) termi-
nal on the terminal block.
1
2
3
Positive/Live (+/L) Terminal
1
Negative/Neutral (-/N) Terminal
2
Surge Ground Terminal
3
Braided Ground Cable
4
Figure 2.5
Terminal Block Wiring
Installing the Device
2.5.1 Connecting High AC/DC Power