2.5.1 Connecting High Ac/Dc Power - Siemens SIMATIC NET RUGGEDCOM RS930L Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS930L:
Table of Contents

Advertisement

Installing the Device
2.5.1 Connecting High AC/DC Power
2.5.1
Connecting High AC/DC Power
To connect a high AC/DC power supply to the device, do the following:
NOTICE
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to terminals for DC power. Damage to the power
supply may occur.
NOTICE
Electrical hazard – risk of damage to equipment
Before testing the dielectric strength (HIPOT) in the field, remove the braided
ground cable connected to the surge ground terminal and chassis ground. This cable
connects transient suppression circuitry to chassis ground and must be removed in
order to avoid damage to transient suppression circuitry during testing.
Note
Torque all terminal connections to 0.6 N·m (5 lbf-in).
1.
12
Secure the power terminal block to the device.
RUGGEDCOM RS930L
Installation Manual, 02/2020, C79000-G8976-1034-06

Advertisement

Table of Contents
loading

Table of Contents