Climate range
The appliance is designed for use within
a certain climate range (ambient tem-
peratures) and should not be used out-
side this range. The climate range of the
appliance is stated on the data plate in-
side the appliance.
Climate range
SN
N
ST
T
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal tem-
perature in the appliance to rise with the
risk of food deteriorating and going off.

Ventilation

If the ventilation gaps given are
not observed, the compressor will
run more frequently and for longer
periods.
This will result in increased energy
consumption and a higher operating
temperature for the compressor. This
may, in turn, cause damage to the
compressor.
It is essential to observe the ventila-
tion gaps given.
Air at the back of the appliance gets
warm. The appliance housing unit must
therefore be constructed to allow suffi-
cient space for ventilation (see "Build-
ing-in dimensions").
Ambient room
temperature
+10 to +32 °C
+16 to +32 °C
+16 to +38 °C
+16 to +43 °C
– Air intake  occurs via the plinth at
the bottom of the appliance and the
air escapes at the top  at the back
of the housing unit.
– A ventilation gap of at least 40 mm
depth must be allowed for behind the
appliance for air to circulate.
– The ventilation cross-sections in the
plinth, housing unit and above the
appliance must each provide an un-
obstructed airflow of at least 200 cm²
to ensure that air can circulate
without hindrance.
If ventilation grilles are to be inserted
into the ventilation gaps, the ventila-
tion gaps must be larger than
200 cm². The unobstructed airflow of
200 cm² is calculated by adding up
the total area of ventilation openings
in the grilles.
– Important! The appliance uses less
energy, the larger the ventilation
gaps.