Preventive maintenance
Introduction
The dehumidifier consists of few moveable parts and otherwise of components of high
quality and long life.
Preventive maintenance in the form of cleaning and regular service should be carried
out to ensure continued operation and to maximise durability. It is important to note
that the intervals between services may vary depending on the environment in which the
appliance is installed.
Service contract
Dantherm A/S offers a service contract that includes preventive and/or corrective
maintenance - see more about this in section "Service agreement", page 35.
Tools
No special tools are required.
IMPORTANT!
The mains connector must always be disconnected before preventive maintenance is
commenced!
If the dehumidifier has been operational, the heating element should be left to cool for
15 minutes before the dehumidifier is dismantled.
Changing the filter
If the appliance is used as a construction dehumidifier, the air filter should be replaced
every third day. Otherwise the filter should be replaced as required depending on the
environment in which the appliance is used.
Carry out the following to replace the filter:
Step
1
Ensure that power to the appliance is disconnected
2
Dismantle the net on the air inlet on the back of the appliance
3
Take out the filter and clean it with compressed air/vacuum cleaner or re-
place, if required
5
Reinsert the filter
6
Mount the net on the air inlet and reconnect the power
Action
Continued overleaf
31