9-3. Auto Restart Function

This indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with
the set operating conditions in the event of a power supply being accidentally shut down.
The operation will resume without warning three minutes after power is restored.

9-3-1. How to Cancel the Auto Restart Function

To cancel auto restart function, proceed as follows :
The power supply to the unit must be on ; the function will not set if the power is off.
Press the [OPERATION] button located in the display of the indoor unit continuously for three seconds.
The unit receives the signal and beeps three times.
The unit will be required to be turned on with the remote control after the main power supply is turned off.
• When the system is on stand-by (not operating)
Operation
Press [OPERATION] button for more than
three seconds. (Less than 10 seconds)
• When the system is operating
Operation
Press [OPERATION] button for more than
three seconds. (Less than 10 seconds)
The unit is on standby.
The unit starts to operate.
After approx. three seconds,
The unit beeps three times and continues to operate.
If the unit is not required to operate at this time, press [OPERATION]
button once more or use the remote control to turn it off.
The unit is in operation.
The unit stops operating.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, press [OPERATION] button
once more or use the remote control to turn it on.