Item
Operation flow and applicable data,etc
26. Fireplace
Fireplace button on remote controller is pressed.
Operation
Fireplace 1:
Cancel cold draft prevention control and fan
speed depend on user require base on basic
control.
Fireplace 2:
Cold draft prevention control is active with super
low fan speed (640 rpm).

Fireplace Operation

27. 8C heating /
8C Button on remote controller is pressed.
Frost protective
Set temperature is performed for 5C to 13C
operation
and no cold draft prevention control.
8C heating operation
8°C
Fireplace#1
Fireplace#2
Normal
operation
8°C
Fireplace#1
Fireplace#2
Normal
operation
- 52 -
Description
Keep air circulation during other heat
source applied.
Note:
With Fireplace operation on heating
mode indoor unit always runs and cold
air breezing might be occurred.
Intended for cold latitudes and
performs objective heating operation.