Minimum Height Of Flue System Exit - Quadra-Fire 31M-ACC-AU Installation Manual

3100 millennium australian wood appliance automatic combustion control (acc)
Hide thumbs Also See for 31M-ACC-AU:
Table of Contents

Advertisement

B. Minimum Height of Flue System Exit
6000mm
increase as necessary until nothing
within 3000mm of fluetop
any nearby structure
Figure 11.1
NOTICE:
Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect
performance.
Chimney height may need adjustment if smoking or
overdraft occurs.
11
3000mm
more than 3000mm
or less
600mm
minimum