Description
J
K
2.5

Overview of the burner bed and the pilot light

A
B
C
D
E
F
G
8
I I tem
Convection casing
DO NOT COVER openings
Item
Grate
Main burner (upper part)
Main burner (lower part)
Pilot light outer casing
Pilot light burner
Thermocouple
Ignition electrode
Description
Collects the heated convection air. The con-
vection air has a natural upward flow and is
extracted by the upper front side openings of
the appliance
Protects the appliance against an overpres-
sure
Description
Combustion air gets in the combustion cham-
ber through the grate around the main burner
Supplies the gas for the main upper fire
Supplies the gas for the main lower fire
Protective cover for the pilot light
Supplies the gas for the pilot light
Detects if the pilot light is on
Supplies a spark to ignite the pilot light