6 Modes and Operating Conditions

6.1 Temperature Parameters Indoor

preset temperature (Tpreset)
Indoor ambient temperature (Tamb.)

6.2 Cooling Mode

When Tamb ≥ Tpreset +1ºC(2ºF) the unit operates in cooling mode. The compressor runs and
the indoor fan operates at the set fan speed.
When Tamb ≤ Tpreset -1ºC(2ºF) the compressor and outdoor fan stop, while the indoor fan
operates at the set fan speed.
When Tpreset-1ºC(2ºF) < Tamb < Tpreset+1ºC(2ºF) the unit stays in its current operating mode.
Under cooling mode the temperature can be set between 61 and 86ºF (16-30ºC).

6.3 Dry Mode

Under this mode the set temperature and ambient temperature won't be displayed. The indoor fan
operates at low fan speed. The compressor and outdoor fan operate continuously.

6.4 Fan Mode

In this mode the set temperature and ambient temperature won't be displayed. The indoor fan operates at
the set fan speed.