21. Remove left and right holders from the
scanner unit.
*: When reattaching the holders in the scan-
ner unit, assemble the parts so that the
holders are in front of the triangle ribs of
the ISU frame.
(If the holders are behind the triangle ribs,
the scanner unit cannot be closed.)
22. Release four hooks and remove the
upper middle cover.
Y116650-5
Holder
2
[Attachment of the right holder]
(Normal)
Upper middle
cover
Hook
Hook
Hook
1-5-59
Scanner unit
Holder
1
1
(Wrong)
Triangle ribs
Figure 1-5-93
Hook
Figure 1-5-94
Service Manual
2PV/2PW-2
2
Holder