Kenmore 795.78733.806 Service Manual page 36

5.11 oz r134a refrigerant
Table of Contents

Advertisement

6-10. Error Code Summary
WARNING: When you check the Resistance values, be sure to turn off the power.
And wait for the voltage-discharge sufficiently.
Error Detection
NO
Category
Normality
1
Freezer Sensor
2
Error
Refrigerator
3
Sensor Error
Defrosting
4
Sensor Error
Icing Sensor
5
Error
6
Poor Defrosting
Abnormality of
BLDC FAN Motor
7
for Ice Making
Abnormality of
BLDC FAN Motor
8
for Freezer
Abnormality of
BLDC FAN Motor
9
for Mechanic
Room
Communication
10
Error
Error Display
Freezer
Ref.
Temperature
Temperature
Er
FS
Er
rS
Er
dS
Er
IS
Er
dH
Er
IF
Er
FF
Er
CF
Er
CO
Error Generation Factors
None
Short or Disconnection
of Freezer Sensor
Short or Disconnection
of Refrigerator Sensor
Short or Disconnection
of Defrosting Sensor
Short or Disconnection
of Icing Sensor
Even though it is passed
1 hour since then Defrosting,
if Defrosting sensor is not
over 8°C, it is caused
It is caused when feedback
signal isn't over 65 seconds
during BLDC FAN motor
operating
It is caused when feedback
signal isn't over 65 seconds
during BLDC FAN motor
operating
It is caused when feedback
signal isn't over 65 seconds
during BLDC FAN motor
operating
Communication Error
between Micom of Main
PWB and Display Micom
- 36 -
Remark
Normal operation of Display
Check each sensor and its
connector.
Temperature Fuse
Disconnection, Heater
disconnection, DRAIN Jam,
Poor Relay for Heater
Poor BLDC Motor
connection, DRIVE IC,
and TR
Poor BLDC Motor
connection, DRIVE IC,
and TR
Poor BLDC Motor
connection, DRIVE IC,
and TR
Poor Communication
connection,Poor TR of
Transmitter and Receiver

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.78739.806

Table of Contents