Checking And Adjusting The Auger/Impeller Cable; Checking The Auger Gearbox Oil Level - Toro 38811 Operator's Manual

Table of Contents

Advertisement

Figure 35
3. Loosen or tighten the turnbuckle to adjust the spring
length to 2.18 inches (5.5 cm).
Figure 36
1. Jam nut
2. Turnbuckle
4. Tighten the jam nut
tension on the cable.
5. If the traction cable is properly adjusted but a problem
remains, contact an Authorized Service Dealer.
Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and adjust
or replace it if necessary.
1. Loosen the jam nut.
2. Engage the auger/impeller lever and hold it in place
(Figure
37).
3. Spring
4. 2.18 inches (5.5 cm)
(Figure
36), ensuring there is slight
3. Loosen or tighten the turnbuckle to adjust the spring
length to 2.75 inches (7 cm)
1. Jam nut
2. Turnbuckle
4. Tighten the jam nut
tension on the cable.
5. If the auger/impeller cable is properly adjusted but
a problem remains, contact an Authorized Service
Dealer.
Checking the Auger Gearbox
Oil Level
Service Interval: Yearly—Check the auger gearbox oil and
add oil if necessary.
1. Move the machine to a level surface.
2. Clean the area around the pipe plug
20
Figure 37
(Figure
38).
Figure 38
3. Spring
4. 2.75 inches (7 cm)
(Figure
38), ensuring there is slight
(Figure
39).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power max 724 oe

Table of Contents