Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and adjust
or replace it if necessary.
1. Loosen the jam nut.
2. Engage the auger/impeller lever and hold it in place
(Figure 39).
3. Loosen or tighten the turnbuckle to adjust the spring
length to 2.75 inches (7 cm) (Figure 40)
g019047
1. Jam nut
2. Turnbuckle
4. Tighten the jam nut (Figure 40), ensuring there is slight
tension on the cable.
5. If the auger/impeller cable is properly adjusted but
a problem remains, contact an Authorized Service
Dealer.
Figure 39
4
3
Figure 40
3. Spring
4. 2.75 inches (7 cm)
Checking the Auger Gearbox
Oil Level
Service Interval: Yearly—Check the auger gearbox oil and
1. Move the machine to a level surface.
2. Clean the area around the pipe plug (Figure 41).
3. Remove the pipe plug from the gearbox.
4. Check the oil level in the gearbox. The oil should be
3/8 inch (9.5 mm) below the filler opening.
5. If the oil level is low, add GL-5 or GL-6, SAE 80-90
EP gear oil lubricant to the gearbox until the oil level
is 3/8 inch below the filler opening.
Note: Do not use synthetic oil.
6. Install the pipe plug in the gearbox.
2
1
21
add oil if necessary.
Figure 41