CE and Australian Dryers
There is an N.P.T. to B.S.P.T. adaptor included with each dryer, which must be installed to the gas inlet. The adaptor is shipped
in the tumbler.
IMPORTANT: Pipe joint compounds that resist the action of natural, propane, and butane gases must be used.
Heat Input / Gas Consumption / Orifice (Injector) Data
Gas Specifications for Non-CE and Non-AGA Approved
Gas
Type
Natural
*Liquid Propane
Shaded areas are stated in metric equivalents
*
Gas valve's internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input / Gas Consumption / Orifice (Injector) Data (For CE [European] Models Only)
Nominal
Gas
Heating Value
Type
B tu /ft
Natural (I
/I
)
1,000
2H
2E
Natural (I
)
2L
Natural (I
)
2ELL
1,000
*Natural (I
)
2E+
*Butane (I
)
3,175
3+
*Propane (I
)
2,500
3+
Butane (I
)
3,175
3B/P
Propane (I
)
2,500
3P
Shaded areas are stated in metric equivalents
* Gas valve's internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
*** Nominal supply pressure.
Heat Input / Gas Consumption / Orifice (Injector) Data (For AGA [Australian] Models
Gas Specifications for AGA Approved Dryers (Australia)
Gas
Type
Natural
Propane
Shaded areas are stated in metric equivalents
* Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
14
Nominal
Supply
Heating Value
Pressure
B tu /ft
3
in WC
1,000
7.0-13.0
2,500
11.0
Gas Specifications for CE Approved
Supply
Pressure***
Heat Input
3
mb
Btu/hr
15-30
110,000
830
20-35
110,000
830
15-30
110,000
20
110,000
25
830
110,000
28-30
110,000
37
110,000
28-30/50
110,000
28-30/50
110,000
Supply
Gross
Pressure
Heat Input
kPa
MJ /h
1.7-3.2
116.06
2.75
116.06
American Dryer Corp.
Gross
Orifice Size
Heat Input
Btu/hr
kW
DMS
110,000
32.241
22
110,000
32.241
44
Gross
Fuel
Consumption
kW
3
32.24
3.115 M
/H
3
32.24
3.753 M
/H
3
32.24
3.753 M
/H
3
32.24
3.115 M
/H
3
32.24
3.753 M
/H
32.24
2.324 kg/H
32.24
2.324 kg/H
32.24
2.324 kg/H
32.24
2.324 kg/H
Orifice Size
DMS
mm
22
3.988
2.184
44
Dryers**
Burner
Orifice
Pressure
(Injector)
Quantity
mm
in WC
3.9878
2
3.0
2.1840
2
10.0
Dryers**
Orifice
Orifice Size
(Injector)
Quantity
DMS
mm
3.988
22
2
22
3.988
2
22
3.988
2
31
3.048
2
3.048
31
2
48
1.930
2
48
1.930
2
44
2.184
2
2.184
44
2
Only)*
Burner
Orifice
Pressure
(Injector)
Quantity
kPa
2
0.69
2.49
2
Burner
Pressure
mb
6.9
9.5
9.5
—
—
—
—
18.1
24.9
113014 - 14
Need help?
Do you have a question about the HB50 and is the answer not in the manual?
Questions and answers