3.12 Alarm
NO (Number)
PRI (Priority)
FUN (Function)
IN (Input)
OUT (Output)
HLD (Hold)
LATCH
DWELL
ALARM: alarm output is operated during an alarm operation or by the short key of our
keyboard.
1 ~ 5 MIN (minute): alarm output is operated during this setting time only by the function run
NOTE: This 1 ~ 5 MIN setting is not operated by an alarm.
There are 5 levels of priority. The function can be selected by Preset, Auto scan, Pattern or Tour
and "0" is the highest priority. Lower priority alarms won't be serviced until the higher priority
alarm is completed. Equal priority alarms will be serviced repeatedly with the dwell time.
NO PRI FUN IN
1
1
001 NO
2
1
--- OFF
3
1
--- OFF
4
1
--- OFF
DWELL
ALARM OUT SETUP
SAVE AND EXIT(ESC TO CANCEL)
alarm input number
the lower number has higher priority (0 ~ 4)
Stored function number to be called by alarm.
NO/NC – normally open/closed, OFF – ignore
OUT1 ~ OUT2 – 5VTTL output, OFF – no output
Alarm will be held for programmed time. (03 to 99 seconds)
ON – Alarm message will remain on the screen even though alarm input is
deactivated.
OFF – Alarm message will disappear from the screen after programmed
hold time when alarm input is deactivated.
means the dwell time during multiple alarms, 03 to 99 seconds.
ALARM OUT SETUP
OUT1
: ALARM
OUT2
: 1 MIN
EXIT(ESC TO EXIT)
of the dome menu or the short key of our keyboard.
ALARM SETUP
(CTRL KEY)
OUT
HLD
OUT1 03
OFF
03
OFF
03
OFF
03
: 03 SEC
22
LATCH
OFF
OFF
OFF
OFF