P25 Condition Mode

Press [Function] + [Scroll Control] key to go to P25 Condition mode in Volume / Squelch Adjust mode.
You can see the current status of APCO decoding and the threshold values in this mode.
T 1. 25 1. 58 1. 80 indicates the threshold voltage. The specific values will be determined by your setup.
The number following ERR: indicates the APCO decoder error rate.
This number preceding AUTO shows threshold value.
Press [Scroll Control] key or [Function] + [Scroll Control] key to quit the P25 Condition Mode. This mode
doesn't have a time-out.

State Transition Diagram

Push [Scroll Ctrl]
Friday, November 07, 2008
PRI
System 1
25. 0000MHz
NFM
ERR: 14
T 1. 25
Push [Scroll Ctrl]
Normal Mode
Push [F]+[Scroll Ctrl]
Push [F]+[Scroll Ctrl]
Squelch Adjust
P25
8 AUTO
1. 58
1. 80
P25 Condition
Volume Adjust
Push [Scroll Ctrl]
Push [F]+[Scroll Ctrl]
27
3. 87
Battery Voltage
Push [F]+[Scroll Ctrl]