Volume (0 ≤ Min ≤ Start ≤ Max ≤ 100)
y Decide to apply volume policy of 'Start Volume', 'Maximum Volume' and 'Minimum Volume'
y
as Yes(Work) or No(Do Not Work).
- Start Volume
This entry sets the start volume level when is power on.
y The level is specified as a number between minimum volume to maximum value. (Min ≤ Start
y
≤ Max)
y The default setting is 'Off' (disabled).
y
y When enabled, if the value is lower then the minimum specified in the minimum volume entry,
y
the minimum volume entry must be used.
y When enabled, if the value is larger then the maximum specified in the maximum volume
y
entry, the maximum volume value must be used.
y Access to a volume in 'On Timer' must be fixed to start volume when 'Hotel Mode Operation'
y
(Yes) and 'Start Volume' (Off, 0 ~ 100) were set simultaneously.
- Maximum Volume
This entry sets the maximum volume level the set. The level is specified as a number between
'Minimum Volume' to 100. (Min ≤ Max ≤ 100)
y If the command volume up to higher than maximum volume' is received, that should be
y
ignored.
y The default value is 100.
y
- Minimum Volume
This entry sets the minimum volume level the set will produce.
y The level is specified as a number between 0 to 'Maximum Volume'. (0 ≤ Min ≤ Max)
y
y If the command volume down to lower than minimum volume is received, that should be
y
ignored.
y The default value is 0.
y
4
Key Operation (v3.0)
y Manage key usability of Local(Front) Key and Remote Control. When selected to 'Yes', following 'IR
y
Operation' and 'Local Key Operation' will be worked by below.
- IR Operation
Decide whether work the LG remote control or not.
y Able to set Normal, Use PWR Only, Block All.
y
y When 'IR Operation' is set to Block All, all normal remote keys don't work. Use PWR Only (Block
y
except power) makes block all remote keys except power key.
y Although 'IR Operation' value is Use PWR Only or Block All.
y
» It can work in 'Service mode'. (In-Start, In-Stop, Power-Only, ADJ, Hotel-Mode, Hotel-Mode-
Ready, P-Check, S-check, In-Time, FMode-Init, FMode-Start, FMode-AV, FMode-F1)
» Menu key action to enter the 'Installation Menu' and key action with 'Special menu(In-Start /
EZ-Adjust ...)' are still available.
y When 'IR Operation' is set to 0 (Work), all remote keys are available.
y
- Local Key Operation
Decide to operate 'Local/Front Key' working behavior by setting 'Local Key Operation' as
Normal, Use PWR Only, Block All. (* LX30* C series use only Normal/Block All)
y When 'Local Key Operation' is set to Block All, all local keys don't work. If value is Use PWR
y
Only, it blocks all local keys except power key.
y When 'Local Key Operation' is set to Normal, all local key are available.
y
Exception)
In case of power off condition with all key are blocked, 'Power On Status' value turns to 'PWR',
and disabled status to fix value for power on operation. (fool-proof routine)