INSTALLATION MANUAL
HIGH EFFICIENCY
TUBULAR HEAT EXCHANGER SERIES
MODELS: AHV9*UP / AHC9V*UP / AHL9V*UP
(Two Stage Variable Speed Upflow)
40 - 120 MBH INPUT
(11.7 - 35.1 KW) INPUT
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermostat Chart - AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Thermostat Chart - HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Accessory Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Termination Configuration - 1 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Termination Configuration - 2 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Termination Configuration - 2 Pipe Basement . . . . . . . . . . . . . . . . . . 15
Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Minimum Duct Sizing For Proper Airflow . . . . . . . . . . . . . . . . . . . . . . . 5
Round Duct Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Recommended Filter Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Nominal Manifold Pressure - High Fire . . . . . . . . . . . . . . . . . . . . . . . . 8
Nominal Manifold Pressure - Low Fire . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical and Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SECTION I: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
LIST OF SECTIONS
COMBUSTION AIR AND VENT SYSTEM . . . . . . . . . . . . . . . . . . . . .12
CONDENSATE PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . .19
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
LIST OF FIGURES
Outside and Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . .17
Condensate Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Pressure Switch Tube Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
LIST OF TABLES
(All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Unconfined Space Minimum Area in Square Inch . . . . . . . . . . . . . . .17
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Air Flow Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Field Installed Accessories - Non Electrical . . . . . . . . . . . . . . . . . . . .27
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
271043-UIM-B-0707

Advertisement

Table of Contents
loading

Summary of Contents for Unitary products group AHV9 UP

  • Page 1: Table Of Contents

    INSTALLATION MANUAL HIGH EFFICIENCY EFFICIENCY RATING TUBULAR HEAT EXCHANGER SERIES CERTIFIED MODELS: AHV9*UP / AHC9V*UP / AHL9V*UP (Two Stage Variable Speed Upflow) ISO 9001 Certified Quality 40 - 120 MBH INPUT Management System (11.7 - 35.1 KW) INPUT LIST OF SECTIONS SAFETY .
  • Page 2: Safety

    Figure 1. The plenum must be installed according to the instructions. Unitary Products Group...
  • Page 3 18 inches (46 cm) above the floor, and the furnace must be located with the provisions of 248 CMR 5.08(2)(a)1 through 4. or protected to avoid physical damage by vehicles. Unitary Products Group...
  • Page 4: Ductwork

    In this example, the duct system attached to the plenum has a sufficient area so that the furnace operates at the specified external static pres- sure and within the air temperature rise specified on the nameplate. Providing the return duct is properly sized as well. Unitary Products Group...
  • Page 5: Minimum Duct Sizing For Proper Airflow

    To properly design the ductwork for the build- ing, Refer to the ASHRAE Fundamentals Handbook, Chapter on “DUCT DESIGN” or a company that specializes in Residential and Mod- ular Home duct designs. Unitary Products Group...
  • Page 6: Filters

    (56.6) (2) (41 x 64) (56 x 64) IMPORTANT: If an external mounted filter rack is being used see the instructions provided with that accessory for proper hole cut size. Unitary Products Group...
  • Page 7: Gas Piping

    8,000 feet (2,438 m), see Table 19 Field Installed Accessories - High minimum sizes listed in these instructions and in the codes. The furnace Altitude pressure Switch rating plate and the instructions in this section specify the type of gas Unitary Products Group...
  • Page 8: Electrical Power

    Field wiring to the unit must be grounded. Electric wires that are field installed shall conform to the temperature limitation for 63°F (35°C) rise Use copper conductors only. wire when installed in accordance with instructions. Refer to Table 7 in these instructions for specific furnace electrical data. Unitary Products Group...
  • Page 9: Electrical Wiring

    “OFF” pins, the furnace will operate only in low The black furnace lead must be connected to the L1 (hot) wire fire. from the power supply. The white furnace lead must be connected Unitary Products Group...
  • Page 10: Thermostat Chart - Ac

    271043-UIM-B-0707 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. FIGURE 5: Thermostat Chart - AC Unitary Products Group...
  • Page 11: Thermostat Chart - Hp

    271043-UIM-B-0707 FIGURE 6: Thermostat Chart - HP Unitary Products Group...
  • Page 12: Accessory Connections

    The furnace shall not be connected to any type of B, BW or L vent or vent connector, and not connected to any portion of a factory- built or masonry chimney The furnace shall not be connected to a chimney flue serving a sep- arate appliance designed to burn solid fuel. Unitary Products Group...
  • Page 13: Dimensions

    COMBUSTION AIR / VENT CLEARANCES IMPORTANT: The vent must be installed with the following minimum STANDARD ELBOW LONG (SWEEP) ELBOW clearances, and must comply with local codes and requirements. FIGURE 8: Dimensions Unitary Products Group...
  • Page 14: Home Layout

    Responsibility for the provision of proper adequate venting and air supply for application shall rest with the installer. Vent shall extend high enough above building, or a neighboring obstruction, so that wind from any direction will not create a positive pressure in the vicinity of the vent. Unitary Products Group...
  • Page 15: Termination Configuration - 1 Pipe

    ABOVE HIGHEST tion air or vent pipes be connected together. The combustion air and ANTICIPATED SNOW LEVEL OR GRADE, vent pipes must terminate in the same atmospheric zone. WHICHEVER IS HIGHER FIGURE 11: Termination Configuration - 2 Pipe Unitary Products Group...
  • Page 16: Double Horizontal Sealed Combustion Air And Vent Termination

    A confined space is an area with less than 50 cu.ft (1.42 m ) per 1,000 vent pipe. Btu/hr (0.2928 kW) input rating for all of the appliances installed in that area. The following must be considered to obtain proper air for combus- tion and ventilation in confined spaces. Unitary Products Group...
  • Page 17: Outside And Ambient Combustion Air

    4. The blocking effects of louvers, grilles and screens must be given AIR (b) AIR (a) consideration in calculating free area. If the free area of a specific louver aor grille is not known. FIGURE 17: Outside and Ambient Combustion Air Unitary Products Group...
  • Page 18: Condensate Piping

    IMPORTANT: Condensate must be disposed of properly. Follow local plumbing or wastewater codes. The drain line must maintain a 1/4" per foot (0.635 cm per meter) slope to the drain. Unitary Products Group...
  • Page 19: Safety Controls

    The operation of this control indicates a malfunction in the combustion air blower, heat exchanger or a blocked vent pipe connection. Corrective action is required. These are manual reset controls that must be reset before operation can continue. Unitary Products Group...
  • Page 20 Calculate the furnace input by using one of the following equa- The induced draft blower motor will start and come up to tions. speed. Shortly after inducer start-up, the hot surface igniter will glow for about 17 seconds. Unitary Products Group...
  • Page 21 For altitudes above 2,000 ft. (610 m) the furnace input MUST BE DERATED. Refer to the GAS CONVERSION FOR PROPANE (LP) AND HIGH ALTITUDES IN SECTION IV for information on high altitude conversions. Unitary Products Group...
  • Page 22: Gas Valve

    Refer to Figure 22 for connection details. sooting and eventual clogging of the heat exchanger could occur. Be sure that gas valve regulator cap is in place and burner box to gas valve pressure reference hose is connected. Unitary Products Group...
  • Page 23: Reading Gas Pressure

    Figure 23. CONTINUOUS HEAT HI HEAT BLOWER FAN SPEED DEHUMIDISTAT DELAY DELAY OFF DELAY JUMPER JUMPER JUMPER JUMPER JUMPER VOLTAGE TERMINALS COOLING PROFILE JUMPER BLOWER SPEED JUMPERS FIGURE 23: Furnace Control Board Unitary Products Group...
  • Page 24 R and W terminals. The indoor fan motor is pressure or faulty gas valve. The furnace will lock out for one hour and energized through the W1 heat terminal and runs on the speed selected then restart. on the HEAT tap of the control board. Unitary Products Group...
  • Page 25 IGNITION CONTROL Normal flame sense current is approximately 3.7 microamps DC (µa) Low flame signal warning starts at 1.5 microamps. Low flame signal control lockout point is 0.1 microamps DC (µa) Unitary Products Group...
  • Page 26: Air Flow Data

    NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details. The ADJ “D” tap should not be used. Unitary Products Group...
  • Page 27: Filter Performance - Pressure Drop Inches W.c. And (Kpa)

    17-1/2” CABINETS 1BR0121 BOTTOM RETURN FILTER KIT 1” FILTER 21” CABINETS 1BR0221 BOTTOM RETURN FILTER KIT 1-4” FILTER 21” CABINETS 1BR0124 BOTTOM RETURN FILTER KIT 1” FILTER 24-1/2” CABINETS 1BR0224 BOTTOM RETURN FILTER KIT 1-4” FILTER 24-1/2” CABINETS Unitary Products Group...
  • Page 28: Wiring Diagram

    SECTION X: WIRING DIAGRAM FIGURE 24: Wiring Diagram Subject to change without notice. Printed in U.S.A. 271043-UIM-B-0707 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 271043-UIM-A-0407 Unitary 5005 Norman Products York Group Drive 73069...

This manual is also suitable for:

Ahc9v upAhl9v up

Table of Contents