Watts PWSYS-RO-MAN5 Installation, Operation And Maintenance Manual

Watts PWSYS-RO-MAN5 Installation, Operation And Maintenance Manual

One-piece manifold reverse osmosis system

Advertisement

Quick Links

Installation, Operation
and Maintenance Manual
One-Piece Manifold Reverse Osmosis System
Model PWSYS-RO-MAN5
PURE WATER
Important
Please read the entire manual before proceeding with the
installation and startup. Your failure to follow any attached
instructions or operating parameters may lead to the product's
failure.
Save manual for future reference.
System tested and certified by NSF International
against NSF/ANSI Standard 58 for the reduction
of the claims specified on the performance data
sheet .
Do not use with water that is microbiologically unsafe or
Note:
of unknown quality without adequate disinfection before or after
the system . Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts .
PWSYS-RO-MAN5

Table of Contents

Operational Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Contents of Reverse Osmosis System . . . . . . . . . . . . . . . . . . . . . 3
Tools Recommended For Installation . . . . . . . . . . . . . . . . . . . . . . 3
Drill a Hole for the Faucet in a Porcelain Sink . . . . . . . . . . . . . . . . 3
How to use Quick-Connect Fittings . . . . . . . . . . . . . . . . . . . . . . . 4
Watts Chrome Top Mount Faucet Installation . . . . . . . . . . . . . . . . 5
Adapt-A-Valve™ Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Drain Saddle Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
" Black Tube Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3
8
Green Tube Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Reverse Osmosis Module Mounting . . . . . . . . . . . . . . . . . . . . . . 6
Red Tube Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Check Air Pressure in the Tank . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Tank Elbow Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Blue Tube Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Blue Tube to Faucet Connection . . . . . . . . . . . . . . . . . . . . . . . . . 7
Final Filter Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Startup Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6-Month Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Annual Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Membrane Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Procedure for Extended Non-Use . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Arsenic Facts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Service Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
IOM-WQ-PWSYS-RO-MAN5

Advertisement

Table of Contents
loading

Summary of Contents for Watts PWSYS-RO-MAN5

  • Page 1: Table Of Contents

    How to use Quick-Connect Fittings . . . . . . . . . . . . . . . . . . . . . . . 4 Watts Chrome Top Mount Faucet Installation . . . . . . . . . . . . . . . . 5 Adapt-A-Valve™...
  • Page 2 With proper installation and maintenance, this system will provide barrier that will pass some particles like clean water, but not other you with high-quality water for years to come . All of Watts water particles like arsenic and lead .
  • Page 3: Operational Parameters

    . Step C – Using a 1¼" hole saw, pro- Watts supplies speciality filters that can be used if copper tubing fol- ceed to drill the large hole .
  • Page 4: How To Use Quick-Connect Fittings

    How to Use the Quick-Connect Fittings on the RO Module To make a connection, the tube is simply pushed into the fitting . holds the tube firmly in place without deforming it or restricting flow . Place a piece of tape "...
  • Page 5: Watts Chrome Top Mount Faucet Installation

    STEP 2 STEP 3 Adapt-A-Valve™ Installation Watts Chrome Top Mount Caution: Water supply line to the system must be from the cold Faucet Installation water supply line only. Hot water will severely damage your system. MiNiMUM MaxiMUM Mounting Hole Size 1"...
  • Page 6: Drain Saddle Installation

    STEP 4 STEP 5 Drain Saddle Installation Drill hole and Connect ⁄ " Black Tube from Faucet to the Drain Saddle Drain Saddle fits standard 1¼" – 1½" drain pipes Note: The drain saddle must be mounted IMPORTANT: The black ⁄...
  • Page 7: Red Tube Connection

    STEP 8 STEP 11 Connect the Red Tube from Faucet Connect Blue Tube from to RO Module RO Module to the Tank Step A – Insert the red ⁄ " tube from the faucet into the port on the Step A – Position tank in desired loca- module marked DRAIN .
  • Page 8: Final Filter Installation

    STEP 13 Startup Instructions Final Filter Installation Step A– Turn on the incoming cold water at the angle stop valve . Turn the knob on the Adapt-A-Valve™ by turning coun- terclockwise . Check the system for leaks, and tighten any fittings as necessary .
  • Page 9: 6-Month Maintenance

    6-Month System Maintenance Caution: Before re-installing the filter bowls back on to the sys- Order filter by calling Watts at 1-800-224-1299 tem, check O-rings to make sure they are still in place. Item Needed: EDP# 7100113 Do not over-tighten filter housing. May damage O-ring(s), Includes: cause water leaks, or affect system performance.
  • Page 10: Membrane Replacement

    TDS reduction falls below 75% . membrane to remove from the Note: A water sample may be sent to Watts for a free diagno- housing and discard . sis of your membrane performance. To send a water sample, use two (2) clean containers and fill ½...
  • Page 11: Troubleshooting

    Low/Slow production Low water pressure Assure a minimum of 40psi incoming water pressure. Watts sells a booster pump if home water pressure is low. Make sure water supply is turned on and Adapt-A- Valve™ is all the way open.
  • Page 12: Arsenic Facts

    . This Watts reverse osmosis system is designed to remove up to 98% of pentavalent arsenic . It will not convert trivalent arsenic to pen- tavalent arsenic .
  • Page 13: Parts List

    Parts List GAC POST-FILTER FLOW FAUCET MEMBRANE VESSEL KITCHEN SINK ADAPT-A-VALVE CARBON FILTER MAIN WATER SUPPLY SHUT-OFF VALVE CARBON FILTER SEDIMENT FILTER iteM # edp# desCRiptioN 7100454 Gac Post-Filter DRAIN SADDLE STORAGE TANK 7100446 Carbon Block 7100331 Sediment Filter 7300043 Manifold Bowl 7300046 Manifold Membrane Vessel...
  • Page 14: Service Record

    Service Record date oF pURChase date oF iNstall iNstalled bY date 1st stage sediMeNt 2Nd stage CaRboN 3Rd stage CaRboN FiNal FilteR CaRboN tFM MeMbRaNe (6 MoNths) (6 MoNths) (6 MoNths) (1 YeaR) (2 – 5 YeaRs) Notes:...
  • Page 16: Limited Warranty

    WaRRaNtY: Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s warranty only. For specific product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty.

Table of Contents