Important
Please read the entire manual before proceeding with the
installation and startup. Your failure to follow any attached
instructions or operating parameters may lead to the product's
failure.
Save manual for future reference.
PWSYS-RO-KC4

Table of Contents

Operational Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Contents of Reverse Osmosis System . . . . . . . . . . . . . . . . . . . . . . . . 3
Tools Recommended for Installation . . . . . . . . . . . . . . . . . . . . . . . . . 3
Drill a Hole for the Faucet in a Porcelain Sink . . . . . . . . . . . . . . . . . . . 3
Watts Top Mount Faucet Installation . . . . . . . . . . . . . . . . . . . . . . . . . 5
Adapt-A-Valve™ Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Drain Saddle Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3
8
Reverse Osmosis Module Mounting . . . . . . . . . . . . . . . . . . . . . . . . . 6
Check Air Pressure in the Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Tank Ball Valve Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Start up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6-Month System Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Annual Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Membrane Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Arsenic Facts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Parts List / Unit Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Do not use with water that is microbiologically unsafe or
Note:
of unknown quality without adequate disinfection before or after
the system . Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts .
IOM-WQ-PWSYS-RO-KC4

Advertisement

Table of Contents
loading

Summary of Contents for Watts PWSYS-RO-KC4 Kwik-Change

  • Page 1: Table Of Contents

    Watts Top Mount Faucet Installation . . . . . . . . . . . . . . . . . .
  • Page 2 With proper installation and maintenance, this system will provide membrane in order to balance the concentration of contaminants you with high quality water for years to come . All of Watts water on each side of the membrane . A semi-permeable membrane is a...
  • Page 3: Operational Parameters

    . an objectional taste in water and pin holes may form in the tubing. Watts supplies speciality filters that can be used if copper tubing fol- Step C – Using a 1¼" hole saw, pro- lows the Reverse Osmosis unit .
  • Page 4: How To Use Quick-Connect Fittings For Tubing Connections

    " from end of tube to indicate how far the ing flow . tube should be inserted . The unique Watts Quick-Connect locking Cut the tube square . It is essential that the outside diameter be free of score marks Fitting grips before it seals .
  • Page 5: Watts Top Mount Faucet Installation

    STEP 3 STEP 2 Adapt-A-Valve™ Installation Watts Chrome Top Mount Faucet Installation Caution: Water supply line to the system must be from the cold water supply line only. MiniMuM MaxiMuM Hot water will severely damage your system. Mounting Hole Size 1"...
  • Page 6: Drain Saddle Installation

    STEP 4 STEP 6 Drain Saddle Installation Green Tube Connection Drain Saddle fits standard 1¼" – 1½" drain pipes Step A – Locate green tube attached to the RO Module . Insert the open end of Note: The drain saddle must be mounted the green ⁄...
  • Page 7: Check Air Pressure In The Tank

    STEP 9 STEP 12 Check Air Pressure in the Tank Blue Tube Connection (From The RO Module To Faucet) Note: Check air pressure when tank is empty of water! Check air pressure in the storage tank when you notice a de- Step A –...
  • Page 8: 6-Month System Maintenance

    Replacement of this reverse osmosis membrane should Step D – Repeat this procedure for the be with one of identical specifications as defined by Watts to 2nd filter cartridges . When assure the same efficiency and contaminant reduction perfor- finished, flush your tank mance.
  • Page 9: Membrane Replacement

    TDS reduction falls below 75% . chlorine residual will rapidly convert trivalent arsenic to pentavalent Note: A water sample may be sent to Watts for a free diagno- arsenic . Other water treatment chemicals such as ozone and potas- sis of your membrane performance.
  • Page 10: Troubleshooting

    1. Low/Slow Production Low Water Pressure Assure a minimum of 40psi incoming water pressure. Watts sells a booster pump if home water pressure is low. Make sure water supply is turned on and Adapt-A-Valve™ is all the way open. Crimps in tubing Check tubing and straighten or replace as necessary.
  • Page 11: Parts List / Unit Drawing

    Parts List The reverse osmosis system contains a replaceable treatment iteM # edp# description component, critical for the effective reduction of total dissolved solids 7300068 Adapt-A-Valve™ and the product water shall be tested periodically to verify that the system is performing properly 7300070 Automatic Shut-Off-Valve - ⁄...
  • Page 12: Limited Warranty

    Warranty: Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s warranty only. For specific product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty.