6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit
SAP-K77GHAX
Outdoor Unit SAP-C77GHAX
Cooling
Performance at
Rating Conditions
Full Load Conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
Full Load conditions: Indoor air temperature:
Outdoor air temperature:
Heating
Performance at
Rating Conditions
Full Load Conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
Full Load conditions: Indoor air temperature:
Outdoor air temperature:
Running Amps.
A
Power Input
kW
Running Amps.
A
Power Input
kW
27 C D.B. / 19 C W.B.
35 C D.B.
32 C D.B. / 23 C W.B.
43 C D.B.
Running Amps.
A
Power Input
kW
Running Amps.
A
Power Input
kW
20 C D.B.
7 C D.B. / 6 C W.B.
27 C D.B.
24 C D.B. / 18 C W.B.
Indoor Unit
Fan Motor
Fan Motor
220/230/240V Single phase 50Hz
0.17
0.21
0.022
0.048
0.17
0.21
0.022
0.048
Indoor Unit
Fan Motor
Fan Motor
220/230/240V Single phase 50Hz
0.17
0.21
0.022
0.048
0.17
0.21
0.022
0.048
31
Outdoor Unit
Compressor
3.02
0.700
3.47
0.770
Outdoor Unit
Compressor
2.72
0.610
3.47
0.770
Complete Unit
3.4
0.770
3.85
0.840
Complete Unit
3.1
0.680
3.85
0.840