Performance Data - Bryant HEAT RECOVERY VENTILATOR ERVBBLHA Product Data

Heat/energy recovery ventilators
Table of Contents

Advertisement

HVI Rated Energy Performance
MODEL
MODE
_C
Heat
ERVBBLHA1150
--- 25
Cool
35
Heat
ERVBBLHA1200
--- 25
Cool
35
Heat
HRVBBLHA1150
--- 25
Cool
35
Heat
HRVBBLHA1250
--- 25
Cool
35
Ventilation Performance
EXT. STATIC
PRESSURE
MODEL
PA
25
75
ERVBBLHA1150
100
150
200
25
75
ERVBBLHA1200
100
150
200
25
75
100
HRVBBLHA1150
150
200
25
75
HRVBBLHA1250
100
150
175
NOTE: For additional data points, refer to HVI Directory at www.hvi.org

PERFORMANCE DATA

SUPPLY
NET
TEMP
AIR FLOW
CONSUMED
L/S
CFM
_F
0
32
30
64
0
32
46
97
0
32
66
141
--- 13
22
47
95
31
65
0
32
39
80
0
32
54
114
0
32
79
167
--- 13
31
65
95
39
82
0
32
31
66
0
32
56
119
0
32
--- 13
34
72
95
0
32
31
66
0
32
56
119
0
32
86
182
--- 13
34
72
95
NET SUPPLY
AIR FLOW
IN W.G.
L/S
0.1
84
0.3
74
0.4
70
0.6
58
0.8
41
0.1
105
0.3
93
0.4
86
0.6
70
0.8
50
0.1
83
0.3
75
0.4
71
0.6
59
0.8
43
0.1
110
0.3
98
0.4
89
0.6
71
0.7
64
POWER
SENSIBLE
RECOVERY
(WATTS)
EFFICIENCY
66
61
77
60
137
57
92
49
63
84
60
113
58
169
56
116
41
81
85
69
124
60
114
62
85
69
124
60
197
53
114
62
SUPPLY
CFM
L/S
179
85
156
75
148
71
124
59
87
42
222
106
198
94
183
88
148
71
107
51
175
83
159
75
150
71
126
60
91
43
234
112
208
100
189
91
151
72
136
65
4
APPARENT
LATENT
SENSIBLE
RECOVERY
EFFECTIVE-
MOISTURE
NESS
TRANSFER
75
0.62
71
0.58
69
0.52
80
0.56
72
0.60
69
0.53
66
0.45
86
0.47
81
0
70
0
80
0.08
81
0
70
0
62
0
80
0.08
GROSS AIR FLOW
EXHAUST
CFM
L/S
181
92
158
85
151
77
125
54
88
20
225
106
200
100
186
93
150
75
108
29
176
83
159
75
151
69
127
49
91
21
237
112
211
99
192
91
153
70
138
44
TOTAL
RECOVERY
EFFICIENCY
56
52
CFM
196
181
163
114
43
225
212
198
158
61
175
158
146
103
45
237
210
193
149
94

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heat recovery ventilator hrvbblhaErvbblhaHrvbblha

Table of Contents