Page 1
S40HT SERIES Submersible High Temperature Sump & Effluent Pumps Safety Instructions Installation and Service Manual Automatic and manual models. Single phase power only - 115 volt 23833A403...
NEVER operate a pump with a power cord that has place. frayed or brittle insulation. IMPORTANT! F. E. Myers is not responsible for losses, NEVER let cords or plug lay in water. injury or death resulting from a failure to observe these...
195°F (90°C). Also pumps are not to be used S40HT series pumps use a 4/10 HP shaded pole, 1550 in environments where ambient temperatures exceed RPM motor, and are available in 115 volt, single phase.
OR WETWELL. ALL PUMP REPAIRS SHOULD BE DONE AT AN (f) Level control ball or weight may be stuck on AUTHORIZED MYERS SERVICE CENTER. side of basin. Be sure it floats freely. (2) Pump runs but does not deliver flow.
(3) Remove the o-ring from the remaining pump (10) Replace oil in the motor housing using only Myers assembly. Clean surface area and place new o-ring submersible transformer oil. The level should be ¾” into position. Be careful not to cut o-ring when below the top of the motor housing.
Page 7
SUMP & RESIDENTIAL SEWAGE During the time periods and subject to the conditions hereinafter set forth, F. E. Myers will repair or replace to the original user or consumer any portion of your new MYERS product which proves defective due to defective materials or workmanship of MYERS.