TWO-WIRE THERMOSTAT
INSTALLATION WIRING
Two-Wire Thermostat
L
L
R
W1
Resistor
(If Required)
C
HVAC Equipment
If the Two-Wire thermostat is losing time or
showing PF or P- it may be neccessary to
install the 10 watt 250 ohm resistor that
is supplied with the thermostat.