Table of Contents

Advertisement

550 / 550 HA
Installation Guide
A31003-H8100-J100-01-7631

Advertisement

Table of Contents
loading

Summary of Contents for Atos Unify OpenScape Branch 550

  • Page 1 550 / 550 HA Installation Guide A31003-H8100-J100-01-7631...
  • Page 2: Table Of Contents

    Contents History of Changes ......................4 OpenScape Branch 550 / 550 HA– Introduction ............5 About this Guide ....................5 Symbols ......................6 Scope of Delivery ....................7 Accessories and Spare Parts ................8 Shipment, Packaging and Unpacking ..............9 Security Information ...................9 Safety Information .....................9 General Safety ....................9 Safety with electricity ..................
  • Page 3 OpenScape Branch 550 / 550HA Storage ............. 40 OpenScape Branch 550 / 550HA Transportation ............ 40 Technical Data ......................41 Block Diagrams ....................41 Standard Interfaces ..................42 Sangoma card: TE130 Series TE131/TE132/TE133/TE134 ........42 Sangoma card: TE430 Series TE435B/TE435/TE436B/TE4364 ......42 Sangoma card: TE230 Series TE235B/TE235/TE236B/TE236 .......
  • Page 4: History Of Changes

    History of Changes Issue Date Summary 09/2021 First issue of the guide. A31003-H8100-J100-01-7631, 09/2021 OpenScape Branch 550 / 550HA, Installation Guide...
  • Page 5: Openscape Branch 550 / 550 Ha- Introduction

    OpenScape Branch 550 / 550 HA– Introduction OpenScape Branch is a Session Initiation Protocol (SIP) based appliance used in a Voice over IP enterprise communication environment for OpenScape Voice solutions to empower the remote branch office. 1.1 About this Guide This guide focuses on describing the special features of the OpenScape Branch 550 (OSB 550) and OpenScape Branch 550HA (OSB 550HA).
  • Page 6: Symbols

    1.2 Symbols The following symbols may be used in this guide. DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. NOTICE indicates a property damage message.
  • Page 7: Scope Of Delivery

    Protective Earth (PE)! This symbol marks the connection point for protective conductor (PE) on the device. This symbol indicates general information about the product and the guide. This symbol also indicates detail information about the specific product configuration. This symbol precedes helpful hints and tips for daily use. 1.3 Scope of Delivery Check that your delivery is complete, and contains the items listed in Table 1: Scope of delivery.
  • Page 8: Accessories And Spare Parts

    Accessories and Spare Parts Table 2: Accessories Rack Slide Rails Kit contents for KISS 2U/4U Systems Slide rails Rack mounting bracket for 2U/4U systems Plate with 2XM6 threaded holes Countersunk head screw M6X10 Countersunk head screw M4X10 NOTE: The “Rack Slide Rails Kit” includes the slide rail kit for KISS 1U as well as for KISS 2U/4U V2 Systems.
  • Page 9: Shipment, Packaging And Unpacking

    Part Number Part Description F31505-E21-A1 F31505-E21-A2 F31505-E21-A3 F31505-E21-A4 F31505-E21-A6 F31505-E21-A7 F31505-E21-A101 F31505-E21-A102 F31505-E21-A103 F31505-E21-A104 F31505-E21-A106 F31505-E21-A107 Shipment, Packaging and Unpacking The OpenScape Branch 550 / 550 HA is packed together with all standard parts in a product specific cardboard packaging with suitable shock absorbers inside. Each item is packaged separately.
  • Page 10 • During a thunderstorm, do not connect or disconnect lines and do not install or remove boards. • If supplied with a power cable, only use the supplied power cable. • Replace the power cable immediately if it appears to be damaged. •...
  • Page 11 • Always wear a hard hat where there is a risk of injury from falling objects. • Make sure that the work area is well lit and tidy. • Sudden changes in temperature can result in condensing humidity. If a communication system or server is transported from a cold environment to warmer areas, for example, this could result in the condensation of humidity.
  • Page 12: Safety With Electricity

    Safety with electricity The new OpenScape Branch 550 / 550HA product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation.
  • Page 13: Lithium Battery Precautions

    It is particularly important to observe standard anti-static precautions when changing piggybacks, ROM devices, jumper settings etc. If the product contains batteries for RTC or memory backup, ensure that the product is not placed on conductive surfaces, including anti-static plastics or sponges. They can cause short circuits and damage the batteries or conductive circuits on the product.
  • Page 14: Electrostatic Discharge (Esd)

    Electrostatic Discharge (ESD) A sudden discharge of electrostatic electricity can destroy static-sensitive devices. Proper packaging and grounding techniques are necessary precautions to prevent damage. Always take the following precautions: Transport ESD-sensitive products in ESD-safe containers such as boxes or bags. Keep electrostatic sensitive parts in their containers until they arrive at the ESD- safe workplace.
  • Page 15: Lightning Protection Requirements

    Risk of electric shock through contact with live wires! Use separate ground wires to provide protective grounding (PE) for the OpenScape Branch 550 / 550HA communication system and possibly any main distribution frames being used. Connect your communication system and your main distribution frame to the ground wire before starting up the system and connecting telephones and lines.
  • Page 16: Thermal Considerations

    1.6 Thermal Considerations Active Cooling The OpenScape Branch 550 / 550HA is forced air-cooled using two internal system fans that force air to flow from the front to the back of the chassis. The processor and expansion cards have integrated cooling solutions or are equipped with corresponding cooling devices.
  • Page 17: Quality And Environmental Management

    1.7 Quality and Environmental Management Unify Software and Solutions GmbH & Co. KG aims to deliver reliable high-end products designed and built for quality, and aims to complying with environmental laws, regulations, and other environmentally oriented requirements. Unify Software and Solutions GmbH & Co. KG is certified for its Quality Management System according to ISO9001 and for its Environmental Management System according to ISO 14001.
  • Page 18: The Openscape Branch 550/ 550Ha- Overview

    The OpenScape Branch 550/ 550HA- Overview The OpenScape Branch 550 is designed for high performance, reliability and offering total flexibility with installation options in a 19” industrial rack or on a desktop. The OpenScape Branch 550HA has a redundant power supply and is otherwise identical to the OSB 550.
  • Page 19: Openscape Branch 550 / 550Ha Models

    2x 1 Gb (1x i219LM & 1x i210AT) 10/100/1000 Mbit/s ATM 12.0 /vPro support Teaming support Display 1x DVI-D (1920 x 1200 @60 Hz) 2x Display Port V 1.2 (4096x2304 @60Hz) PS/2 Keyboard, Mouse Audio 1x Line in, 1x Line out 1x Microphone 1x RS232 Serial Port...
  • Page 20: Openscape Branch 550 / 550Ha Variants

    1B433LF 1A4B05F OSB 550HA 4x FXO 4x FXS OSB 550HA 1A4B02F 1A4B05F 1x E1 PRI 4x FXS OSB 550HA DP14 1TE131F 1A4B05F 2x E1 PRI 4x FXS OSB 550HA DP24 1TE235BF 1A4B05F 4x T1/E1 PRI OSB 550HA 1TE435BF 8x T1/E1 PRI OSB 550HA 1TE435BF 1TE435BF...
  • Page 21 Max. number of SIP trunking sessions Number of FXO ports Number of BRI ports2 Number of E1/T1 PRI ports Max. number of concurrent integrated gateway calls Number of Analog Terminal Adapter ports (FXS) Max. number of concurrent Voice Mail Calls Max.
  • Page 22: General Instructions On Usage

    2.4 General Instructions on Usage In order to maintain the product warranty, this product must not be altered or modified in any way. Changes or modifications to the product, that are not explicitly approved by Unify Software and Solutions GmbH & Co. KG and described in this guide or received from Unify Software and Solutions GmbH &...
  • Page 23: Minimum System Clearance

    Minimum System Clearance To guarantee that sufficient air flows from the front to the back of the chassis, ensure that the ventilation holes are not covered, blocked or obstructed by surrounding parts. Before installing the OpenScape Branch 550 / 550HA take into account, any thermal considerations mentioned in 1.6 Thermal Considerations, such as airflow obstructions and the correct mount orientation.
  • Page 24: Front Side

    Front Side The front side consists of two handle brackets for installation in a 19” Industrial rack. Figure 1: OSB 550 / 550 HA front side 1. Power button 3. Unify logo 2. LED indicators 4. USB (2.0) ports Figure 2: Handle bracket with fastening screws 1.
  • Page 25: Usb Ports

    2.5.1.2 USB Ports The two USB 2.0 ports are located on the front side of the product. Figure 3: Power button and USB 2.0 ports 1. Power button 2. USB (2.0) ports 2.5.1.3 Controls and Indicators Power Button The power button is located on the front side of the product. Press the power button to switch on or switch off the product.
  • Page 26 Power LED and HDD Activity LED The indicators are located on the front side. Figure 4: LED indicators Power LED HDD activity LED Table 7: Power LED and HDD LED activity description Power LED LED illuminates (green) when the product is switched on by pressing the power button.
  • Page 27: Rear Side

    Rear Side The rear panel includes the external interfaces of the integrated mainboard, any expansion cards interfaces/ports, power supply unit (PSU) sockets , and air exhaust ventilation holes. The positioning and number of interfaces varies depending on the system configuration. Figure 5: Rear side of OSB 550 1.
  • Page 28 Figure 6: Rear side of OSB 550HA 1. Input power sockets 5. Slot brackets for: 2. Power Supply Unit (PSU) Slots 1-2: gateway cards 3. Mainboard external interfaces Slots 3-4: reserved; no usage allowed 4. Rear side of the cover with three knurled screws 6.
  • Page 29: External Interfaces

    2.5.2.1 External Interfaces Depending on the installed mainboard, the following external interfaces are available for peripherals. Figure 7: External mainboard interface panel OpenScape Branch 550 / 550 HA 1. Mouse 7. LAN2 2. Keyboard 8. 2x USB 3.1 (Gen 2) Type A 3.
  • Page 30 AC Power cable and power connectors must always remain easily accessible. If the end environment restricts access to the power cable, disconnection must be guaranteed using a separate cut-off fixture. Do not disconnect the power from the product while the product is switched on! Performing a forced shut down may lead to loss of data or other undesirable effects! Switch off using the power button to perform an orderly shutdown without data loss.
  • Page 31: Mainboard

    Mainboard Figure 10: Configuration with micro-ATX mainboard and low profile expansion cards 1. Cover retaining plate on the front 6. Fastening screws for the slot side brackets 2. Cover retaining plates on the rear 7. Mainboard side 8. Fans (of the fan assembly) 3.
  • Page 32: Openscapebranch 550 / 550Ha Installation

    The following slots are available on the rear side of the chassis. Table 8: Low Profile cards slots Installed Low Profile cards Mainboard micro-ATX Up to 4x PCIe (low profile) (CFL) 1. Slot 1: x16: 1x 16 lanes, Gen3 (Reserved for OSB 550 Card 1) 2.
  • Page 33: How To Install As A Desktop

    Before connecting any I/O cables, ensure that protective grounding (PE) is connected, the product is switched off and the power cable is disconnected connected from the power connector or mains power. When connecting cables, following proper cabling procedures: 1. Grounding pin is connected first and disconnected last. 2.
  • Page 34: How To Install In A 19" Industrial Rack

    3.2 How to Install in a 19" Industrial Rack Before installing the OpenScape Branch 550 / 550HA in a 19" industrial rack, observe the instructions in 1.5.1 General Safety. Install only in a stable 19" industrial rack cabinet. To improve stability: Place system from the bottom up Place heavy systems lower down Bolt the cabinet to the floor or anchor the cabinet to the wall...
  • Page 35: How To Install And Remove Low Profile Expansion Cards

    3.3 How to Install and Remove Low Profile Expansion Cards To install or remove low profile expansion cards (Table 8: Low Profile cards slots), proceed as follows: Observe the General Safety Instructions within this user guide (1.5. Safety Information). Switch off and disconnect the product from the mains power supply. Install a low profile expansion card by removing the slot bracket’s fasten screw and retaining the slot bracket with screw for later use.
  • Page 36: Openscape Branch 550 / 550Ha System Startup

    Handling and operation of the product is permitted only for trained personnel aware of the associated dangers, within a work place that is access controlled and fulfills all necessary technical and environmental requirements. Follow the electrostatic discharge (ESD) precautions for components that are sensitive to ESD and use a clean, flat and ESD-safe surface when handling the product.
  • Page 37: How To Connect The Power Connection

    3.6 How to connect the Power Connection The input power socket is located on the rear side. To connect the power and start up, proceed as follows: Connect the ends of the supplied AC power cable to the corresponding sockets: •...
  • Page 38: Serviceability Features

    Serviceability Features 4.1 OpenScape Branch 550 / 550HA Maintenance Unify Software and Solutions GmbH & Co. KG systems only require minimal maintenance and care to maintain correct operation. Wipe the product with a soft dry cloth if required Remove persistent dirt using a soft, slightly damp cloth (only use a mild detergent). 4.2 How to Replace the Fan Assembly Before replacing the fan assembly, read the following instructions: Operation is permitted only with a functional fan assembly!
  • Page 39: How To Replace The Lithium Battery

    Figure 13: Removing the fan assembly 1. Fan assembly 2. Two knurled screws To replace with a new functional fan assembly, align the fan assembly with the fan compartment. Push the fan assembly carefully into the fan compartment until the fan assembly’s control connector is firmly inserted into the internal fan power control socket.
  • Page 40: Openscape Branch 550 / 550Ha Storage

    Pay attention to the polarity of the battery. Replace the lithium battery only with the same type of battery or with a type of battery recommended by Unify Software and Solutions GmbH & Co. KG. Reinstall the removed expansion cards and reattach the connecting cables. 4.3 OpenScape Branch 550 / 550HA Storage If the product is not in use for an extended period time, disconnect the power plug from the mains power source.
  • Page 41: Technical Data

    Technical Data This chapter lists the main OpenScape Branch 550 / 550HA technical specifications. 5.1 Block Diagrams Figure 14: Block diagram OpenScape Branch 550 / 550HA Low Profile KISS 2U Short V3 CFL Low Profile micro-ATX Mainboard 1x PCIe x1 Gen 3 1x PCIe x16 Gen 3 (4 lanes) 2280 2x System Fans...
  • Page 42: Standard Interfaces

    5.2 Standard Interfaces Sangoma card: TE130 Series TE131/TE132/TE133/TE134 Signal Name Connector RJ45 Telco Port Connector Not used Not used Not used Not used Sangoma card: TE430 Series TE435B/TE435/TE436B/TE4364 Signal Name Connector RJ45 Telco Port Connector Not used Not used Not used Not used A31003-H8100-J100-01-7631, 09/2021 OpenScape Branch 550 / 550HA, Installation Guide...
  • Page 43: Sangoma Card: Te230 Series Te235B/Te235/Te236B/Te236

    Sangoma card: TE230 Series TE235B/TE235/TE236B/TE236 Signal Name Connector RJ45 Telco Port Connector Not used Not used Not used Not used Sangoma card: A4A / A4B Signal Name Connector Not used RJ11 Telco Port Connector Not used Ring Not used Not used 5.3 Environmental Specification Temperature Description...
  • Page 44 Temperature Description 0 °C to +50 °C (+50°F to +122 °F) Temperature Operating -20°C to +70°C (-4°F to +158°F) Storage & Transit 10-93 % @ 40° C, non condensing Relative Operating and Humidity Storage & Transit Environment Description Vibration Operating 10 Hz –...
  • Page 45: Ce Directives And Standards

    5.4 CE Directives and Standards The OpenScape Branch 550 / 550HA complies with the European Council Directive and the approximation of the laws of the member states. If modified, the prerequisites for specific approvals may no longer apply. Unify Software and Solutions GmbH & Co. KG is not responsible for any radio television interference caused by unauthorized modifications of the product or the substitution or attachment of connecting cables and equipment other than those specified by Unify Software and Solutions GmbH &...
  • Page 46 Unify, OpenScape, OpenStage and HiPath are registered trademarks of Unify Software and Solutions GmbH & Co. KG. All other company, brand, product and service names are trademarks or registered trademarks of their respective holders. atos.net A31003-H8100-J100-01-7631, 09/2021 OpenScape Branch 550 / 550HA, Installation Guide...

This manual is also suitable for:

Unify openscape branch 550 ha

Table of Contents