in cases that the fuel tank ran out of pellets and new lighting process is need.
The feed system must be completely full of pellets for the lighting of the stove, otherwise
it could fail.
EN
Messages/alarms
The control system is constantly monitoring the behaviour of the stove and controls all the
components, if any component registers a malfunction during the lighting process or in work
an alarm message will be shown on the display and the stove will turn off for safety.
In case of alarm, one of the following messages will appear:
Code
Er01
Er02
Er03
Er05
Er07
Er11
Er12
Er15
Er17
Er39
Er41
Description
High temperature in
pellet tank
High pressure in
exhaust gases outlet
Low exhaust gases
temperature
High exhaust gases
temperature
Exhaust gases
extractor error –
encoder
Time and day not
correct after a long
period without power
supply
Lighting fail
Power supply fail
Error in the
combustion air
sensor
Failure in the
combustion air
sensor
Minimal air flow in the
lighting process not
reached.
Cause
Maintenance /
cleaning
Obstructed chimney
No pellets in the tank
Maintenance /
cleaning
Burner not clean / low
debt of pellets
Power supply fail
EN // 122
USER'S MANUAL
Solution
Clean the stove according to
this manual, if the problem
remains call assistance.
Clean the chimney.
Refuel the tank and load the
pellet feeder before turn on.
Clean the stove according to
this manual, if the problem
remains call assistance.
Call assistance.
Set time and day according to
this manual.
Clean the stove according to
this manual before trying a
new lighting, load the pellet
feeder.
Reset the alarm.
Call assistance.
Call assistance.
Try lighting again. Clean
the stove according to this
manual, if the problem
remains call assistance.