Quick Settings Menu - IKOS MONO User Manual

Table of Contents

Advertisement

Available languages

Available languages

Menus

Quick settings menu

EN
Status visualization
Power adjustment
while working
Pellet load
Recipe
Exhaust gases
extractor
Ambiance
temperature
adjustment
Pressing repeatedly in P1 button:
tF: Exhaust gases temperature
tA: Ambience temperature
FL: Combustion air flow
UF: Exhaust gases ventilator speed
Co: Pellet feeder working time
FC: Program code
494: Product code
Pressing the P3 button will show the current operating power blinking on the
D2 display. Press P3 again to adjust the desired power. Ex.: 1- 2-3-4-5-A
(A= Automatic Combustion). After 5 seconds the new value is saved and the
display will be back to the initial state. NOTE: In all cases, the power always
depends of the temperature set by the user.
Hold down P3 button for a few seconds and the system will keep the pellet
feeder in continuous work. The bottom display will show "Load" and the top
display the work time. To stop the loading process just press any button. If no
button is pressed the pellet loading will stop after 300 seconds. NOTE: This
function is only accessible if the stove is not in operation.
Depending of the quality of the pellets used, it's possible to adjust slightly the
pellet debt. To access this function press and hold down P2 until the bottom
display shows the message "PELL". Hold down P2 button again until a "bip"
sound is heard. After this you can increase (P2 button) or decrease (P4
button) the pellets recipe value to the desired value. After 5 seconds the new
value is saved and the display returns to the initial message.
Depending of the chimney stove there might be the need to adjust the
exhaust gases extractor. To access this function hold down P4 button until
the message "UEnt" shows in the bottom display. Press the P4 button again
until a "bip" sound is heard. After this you can adjust the extractor speed
level increasing it with the P2 button and decreasing it with the P4 button.
After 5 seconds the new value is saved and the display returns to the initial
message.
To adjust the room temperature, press one of the buttons, P2 or P4, and use
them to select the desired room temperature. After 5 seconds the action will
be recorded.