CONNECTING REGULATOR TO THE LP TANK
1. Check the tank valve to ensure it has proper external mating threads to fit the hose and regulator assembly
provided (Type 1 connection per ANSI Z21.58b-2002).
2. Make sure all burner knobs are in the OFF position.
3. Remove the protective cap from the LP tank valve and coupling
nut. And inspect the valve connection port of the regulator
assembly. Look for damage or debris. Remove any debris. Inspect
hose for damage. Never use damaged or plugged equipment.
4. Hold regulator by one hand in a straight line with LP tank valve
and insert nipple into LP tank valve. Be sure the nipple is centered
in the valve outlet. (see Fig. 1). Hand-tighten the coupling nut clockwise
until it comes to a full stop. DO NOT use tools!
5.
Open the tank valve fully (counterclockwise).
6. Perform leak test before attempting to light your grill.
See "CHECKING FOR LEAKS " on page 19.
WARNING
: The Type I connective coupling (see Fig. 2) supplied with your grill must not be replaced
with a different type of grill/tank connection system. Removal will result in loss of warranty, gas leakage, fire
and severe bodily harm.