Annovi Reverberi AR 303 Instruction Manual

Annovi Reverberi AR 303 Instruction Manual

Hide thumbs Also See for AR 303:

Advertisement

140° F - Max Water Temp
1" - Suction
1/2" Hose Barb- Outlet
AR303 • AR403 - 550
m
odeL
AR303-SP
AR303-GR3/4-GCI
AR403-SP
AR403-GR3/4-GCI
GCI - Pump with a mounted control unit.
d
K
iAPHRAgm
m
d
odeL
eScRiPTion
AR43289
BlueFlex
AR43287
Desmopan
AR43286
NBR
INSTRUCTION MANUAL
- S
RPm
emi
m
gPm m
Ax
9.2
9.2
10.7
10.7
V
K
ALVe
iTS
iTS
m
d
odeL
AR2388
Valves
-H
T
ydRAuLic
HRee
L/m
m
Ax
in
Ax
34.7
580
34.7
580
40.7
580
40.7
580
o-R
ing
m
eScRiPTion
odeL
AR2389
AR 303
AR 403
d
P
iAPHRAgm
PSi
m
B
HP P
Ax
AR
40
40
40
40
o
K
iL
iTS
d
m
eScRiPTion
odeL
O-Rings
AR64532D
AR64532D-C Case (6)Oil
umP
w
eigHT
L
.
oweR
BS
3.1
19.8
3.1
32
3.7
19.8
3.7
32
d
eScRiPTion
Oil

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR 303 and is the answer not in the manual?

Questions and answers

Summary of Contents for Annovi Reverberi AR 303

  • Page 1 AR 303 AR 403 140° F - Max Water Temp 1” - Suction 1/2” Hose Barb- Outlet INSTRUCTION MANUAL AR303 • AR403 - 550 ydRAuLic HRee iAPHRAgm eigHT gPm m HP P odeL oweR AR303-SP 34.7 19.8 AR303-GR3/4-GCI 34.7 AR403-SP 10.7...
  • Page 2: Drive Options

    Drive Options Gearbox Kit AR1639: 1” 8-18 HP Gas Engines Gearbox Kit AR1636: 3/4” for 5-6HP Gas Engine Gearbox for four stroke engines Gearbox for four stroke engines with SAE J609a flange with SAE J609a flange Ø 1" Ø 1" Shaft Kit AR43394: 1 3/8”...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Intended uses The pump is designed and constructed for incorporation in plants and machinery (spraying machines for the protective treatment of agricultural crops and garden plants). All other uses constitute misuse unless ap- proved by the manufacturer's technical service The pump must be used in a manner appropriate to its technical data (see “Technical Data”), and must not be modified or improperly used.
  • Page 4: Installation

    Installation • The crankshaft may turn in either direction. • The water connection with the pump must be made using hoses of suitable diameter, in all case no less than that of the pump fittings, securing them to the fittings using good quality clamps. The intake hose must be coil-reinforced to prevent restrictions.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS Installation diagram (guideline) The following is a simplified illustration of the typical installation layout and is purely guideline. Control Unit by-pass Tank Agitation plugged strainer or too small a strainer Control Unit Intake filter Pump long inlet hose or too small of hose Delivery line filter...
  • Page 6 INSTALLATION INSTRUCTIONS General guidelines on water supply connection To operate correctly, the diaphragm pump must draw in liquids from containers at atmospheric pressure. Do not supply the pump with pressurised liquids. For continuous duty, the pump should not draw in water by gravity from containers with liquid level at heights above 3 m.
  • Page 7 Safety recommendations for handling and lifting Before starting the operations, organise the intended working area so that the materials can be lifted and handled in safety. Unloading, loading, handling and lifting operations must be carried out by skilled, authorised, specifi­ cally trained staff.
  • Page 8: Preliminary Checks

    Safety recommendations for use Before start-up, the operator must perform the necessary safety checks. In the event of leaks from the pressurized pipes, stop the pump at once and fix the leak. Do not operate the pump above the limits set by the manufacturer to increase its performance. Preliminary checks If the pump has a pressure accumulator, check its level of inflation, see "Checking the inflation pressure".
  • Page 9 Safety recommendations for maintenance Before doing any maintenance work, depressurise the water system and isolate the pump from all en- ergy sources. When the jobs are done, before restarting the pump, check that no tools, rags or other materials have been left close to moving parts or in hazardous zones.
  • Page 10: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS Table of lubricants The pump is delivered complete with high-performance 30 weight, non-detergent oil suitable for the intended ambient conditions (see "Environmental operating limits"). Inspecting the pump mounting Check that the pump's fixing screws have not become loose. If necessary, tighten them with the driving torque stated in the installation design.
  • Page 11: Pump Storage

    Pump Storage It is important to comply with the recommendations for storage in the operator's manual of the machine into which the pump is incorporated. For the pump itself, at the end of pumping operations it is essential to flush out the internal circuit by pump­ ing clean water.
  • Page 12: Troubleshooting

    TROUBLESHOOTING The information provided is intended to provide guidance how to deal with malfunctions which may occur during use. Some of these procedures may be carried out by skilled staff, while others have to be performed at specialised service centres since they require the use of specific equipment as well as detailed knowledge of repair opera­ tions.
  • Page 13 TROUBLESHOOTING Remedy Problem Cause Oil seal on pump Replace the worn oil seal. shaft worn. Oil on pump body or base. Oil pressure inside pump too high. Restore correct oil level in tank. Pump using too much oil (oil flowing from delivery port) or oil Stop the pump at once.
  • Page 14 A.R. NORTH AMERICA A.R. NORTH AMERICA AR 303 - AR 403 38 39 35 36 37 31 32 56 - 1 56 - 2 23 24 56 - 3 56 - 4 56 - 5 56 - 6 2021 AR North America...
  • Page 15 GR3/4-GCI AR 303 - AR 403 31740 31742 AR303 AR403 31743 31745 Code Description Code Description Note Note 550370 Elbow 1" 800090 Hub pin T T 180* 390201 O-ring for C/SP 800091 Hub pin Viton T T 180* 1880130 O-ring Ø...
  • Page 16 T T 90* 880830 O-ring Ø 15.54x2.62 550460 Elbow Ø 18 550450 Ring nut 3/4” G For AR 303 - AR 403 For AR 303 - AR 403 1140450 O-ring Ø 20.24x2.62 1880310 Bolt TCEI M8x65 AR 894 "S" 450145 Flange...
  • Page 17 A.R. NORTH AMERICA A.R. NORTH AMERICA AR 1636 : Gear Reduction Per - For: AR 30 - AR 303 - AR 403 Use of engine : B&S Vanguard 6.5 Kohler SH265 - CH270 Honda GX120 - GX160 - GP160 - GP200 Subaru EX17 - EX21 Ø...
  • Page 18 A.R. NORTH AMERICA A.R. NORTH AMERICA AR 1666 : Gear Reduction Per - For: AR 30 - AR 303 - AR 403 Use of engine : B&S Vanguard 6.5 Kohler SH 265 Kohler SH 270 Honda GX 120 Honda GX 160...

This manual is also suitable for:

Ar 403Ar303-spAr303-gr3/4-gciAr403-spAr403-gr3/4-gci

Table of Contents