Orion 14710 User Manual

In-line meter for grease

Advertisement

USER MANUAL / BRUKSANVISNING / MANUEL D'UTILISATION / BEDIENUNGSANLEITUNG / MANUAL DE INSTRUCCIONES
IN-LINE METER
FOR GREASE
INBYGGNADSMÄTARE
FÖR FETT
Part No. / Réf. / Art. Nr. / Cód.:
14710
Manual 14710_EN_SE_1C 2013-11-08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 14710 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Orion 14710

  • Page 1 USER MANUAL / BRUKSANVISNING / MANUEL D’UTILISATION / BEDIENUNGSANLEITUNG / MANUAL DE INSTRUCCIONES IN-LINE METER FOR GREASE INBYGGNADSMÄTARE FÖR FETT Part No. / Réf. / Art. Nr. / Cód.: 14710 Manual 14710_EN_SE_1C 2013-11-08...
  • Page 2: Installation

    Manual 14710_EN_SE_1C Technical data Meter mechanism Oval gears Maximum flow 70 oz/ min / 2000 g/min Max. working pressure 50 Mpa / 7250 psi Min. burst pressure 100Mpa / 14500 psi Working temp. Min. –Max. +10 – +70 °C / +50 – +158°F Accuracy (after calibration) ±...
  • Page 3: Operation

    Manual 14710_EN_SE_1C Operation Användning Press the reset key (Pos 2, Fig.1) to turn on the meter Tryck på reset knappen (Pos 2, Fig.1) för att nollställa display, which will then be showing 0.000 (Pos 1, Fig. räkneverket (Pos 1, Fig. 1), vilket då kommer att visa 1).
  • Page 4: Troubleshooting

    Manual 14710_EN_SE_1C Trouble shooting Symptom Possible reasons Remedy Faded display Weak batteries Replace batteries No reading in the display Dead batteries Replace batteries Meter has not been reset after battery Press the reset key replacement The oval gear are broken Replace the gears and make sure the working temperature is within normal conditions.
  • Page 5: Meter Calibration

    Manual 14710_EN_SE_1C Meter calibration Calibration of the meter can be necessary as different flow ranges, grease penetration grade and • pressure among other factors, can affect the meters accuracy. Verify that there is no air in the distribution line before starting the calibration. Bleed the distribution line •...
  • Page 6 Manual 14710_EN_SE_1C Kalibrering Kalibrering av mätaren kan ibland vara nödvändig för att säkerställa noggrannheten på mätresultatet. • Detta beroende på olika flödeshastigheter och fettets penetrationsgrad samt speciellt för de nya fetternas vidhäftningsförmåga. Kontrollera att det inte finns några spår av luft i fettet innan kalibreringsproceduren startar. Om det finns •...