MS8250A/B Digital Multimeter
Specification
3.2.8 Frequency
3.2.8.2 Pass Hz grade:
Measuring
Resolution
range
5Hz
0.01Hz
50Hz
0.1Hz
500Hz
0.001kHz
5kHz
0.01kHz
50kHz
0.1kHz
500kHz
1kHz
5MHz
10kHz
Overload protection: 250V DC or AC (RMS) - measurement signal: Vpp3V
AC signal
3.2.8.3 Duty ratio
Measuring range
Resolution
10 - 95%
0.1%
- 12 -
Accuracy
(0.5% reading + 2 digits)
Accuracy
2.0%
MS8250A/B Digital Multimeter
Specification
3.2.9 DC current
Measuring range
Resolution
400A
0.1A
4000A
1A
40mA
10A
400mA
100A
20A
10mA
Overload protection:
A and mA grade: Fuse F400mA/250V, A grade: Fuse F20A/250V.
When measuring current is greater than 5A, the continuous measurement time
should not be more than 10 seconds. After measuring, disconnect the current.
3.2.10 AC current
Measuring range
Resolution
400A
0.1A
4000A
1A
40mA
10A
400mA
100A
20A
10mA
Overload protection:
A and mA grade: Fuse F600mA/250V, A grade: Fuse F20A/250V.
- Frequency range: 50 ~ 60Hz
- Response: true RMS
When measuring current is greater than 5A, the continuous
measurement time should not be more than 10 seconds. After
measuring, disconnect the current.
Accuracy
(0.8% reading + 2 digits)
(1.2% reading + 2 digits)
Accuracy
(1.5% reading + 2 digits)
(3.0% reading + 5 digits)
- 13 -

Hide quick links: