NOTE: Refer to Following Procedures for Proper Method to Perform Maintenance
OIL CHANGE PROCEDURES: Refer to Controls and Feature section for diagram. Periodic
Maintenance of your engine oil should be performed after each 40 hours of use of you
Power Equipment Product. Check your engine oil level prior to each use.
1. Start your engine and let it warm up to get the oil warm and thinner. Turn the engine On/Off
switch to the "OFF" position. Turn Fuel Valve to the "OFF" position.
2. Remove the oil cap/dipstick by turning counter clockwise. Remove the oil drain plug located
below the oil cap/dipstick utilizing the appropriate tools.
USE CAUTION: THE OIL MAY BE HOT.
3. Drain the engine oil into an approved receptacle and discard in accordance with all Federal
and State Regulations. Never dump the used engine oil on the ground or into drains, only
discard in an approved manner. Check with your local authorities to determine the
regulations in your area.
WARNING! AVOID SPLASHING OF HOT OIL; IT CAN BURN YOU AND CAUSE SEVERE INJURY.
4. After oil is completely drained, replace oil drain plug and tighten with appropriate tools.
Replace oil with the proper oil for your product. Refer to the Pre-Operating Instruction:
Generator Setup section for exact fill requirements.
Always use your dipstick to check the oil level and only fill to the full
mark on the dipstick. Never overfill the engine as this can cause
damage to the unit and void warranty.
5. Replace the dipstick/oil cap on the engine.
6. Shake generator to ensure the float in the
Oil Alert System is free.
This unit is equipped with an Oil Drain Extension
(seen here) for easy oil change and maintenance.