Installation - Flotec FP4800 Owner's Manual

Shallow well jet pumps
Hide thumbs Also See for FP4800:
Table of Contents

Advertisement

Installation

To Household
Water System
Typical pump
Not
shown herein
to
not to scale.
Scale
Figure 1 - Driven Point Installation
To Household
Water System
Pump Priming
Tee with Plug
or Gauge
Check
Valve
Not
Min.
to
Scale
5–10'
Figure 2 - Cased Well Installation
Replacing An Old Pump
power to pump before working on pump or motor.
Pump Priming
Tee with Plug
1. Drain and remove the old pump. Check the old pipe for scale, lime,
or Gauge
rust, etc., and replace it if necessary.
2. Install the pump in the system. Make sure that all pipe joints in the
suction pipe are air-tight as well as water tight. If the suction pipe can
suck air, the pump will not be able to pull water from the well.
3. Adjust the pump mounting height so that the plumbing connections do
Priming
not put a strain on the pump body. Support the pipe so that the pump
Tee and
body does not take the weight of piping or fittings.
Plug
You have just completed the well plumbing for your new shallow well jet
pump. Please go to Page 6 for discharge pipe and tank connections.
Check
Valve
Well Point (Driven Point) Installation
Drive point
1. Drive the well, using "drive couplings" and a "drive cap". "Drive
below water
level
fittings" are threaded all the way through and allow the pipe ends to
butt against each other so that the driving force of the maul is carried
Drive
Coupling
by the pipe and not by the threads. The ordinary fittings found in
hardware stores are not threaded all the way through the fitting and can
Drive
Point
collapse under impact. "Drive fittings" are also smoother than standard
plumbing fittings, making ground penetration easier.
2. Mount the pump as close to the well as possible.
3. Use the fewest possible fittings (especially elbows) when connecting
1861 0205 NEW SWJ
the pipe from the well point to the pump suction port. The suction pipe
should be at least as large as the suction port on the pump (include
a check valve if your pump is not equipped with one – see Figure
1). Support the pipe so that there are no dips or sags in the pipe, so
it doesn't strain the pump body, and so that it slopes slightly upward
from the well to the pump (high spots can cause air pockets which can
air lock the pump). Seal the suction pipe joints with PTFE pipe thread
sealant tape or a PTFE-based pipe joint compound. Joints must be air-
Suction Pipe
From Well
and water-tight. If the suction pipe can suck air, the pump cannot pull
water from the well. If one well point does not supply enough water,
consider connecting two or three well points to one suction pipe.
You have just completed the suction piping for your new shallow well jet
Priming
pump. Please go to Page 6 for discharge pipe and tank connections.
Tee and
Plug
Cased Well Installation, 2" or Larger Casing
Sanitary
Well Seal
1. Mount the pump as close to the well as possible.
2. Assemble the foot valve, strainer, and well pipe (see Figure 2). Make
sure that the foot valve works freely.
3. Lower the pipe into the well until the strainer is five feet above the
bottom of the well. It should also be at least 10 feet below the well's
10'
water level while the pump is running in order to prevent the pump
Foot
Valve
from sucking air. Install a sanitary well seal.
1862 0205 SWJ
Risk of electric shock . Can shock, burn or kill. Disconnect
(Figure 1)
(Figure 2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp4000Fp4100

Table of Contents