Flotec FP4200 Series Owner's Manual
Flotec FP4200 Series Owner's Manual

Flotec FP4200 Series Owner's Manual

Convertible deep well jet pumps
Hide thumbs Also See for FP4200 Series:

Advertisement

P.O. Box 342, Delavan, WI 53115
Phone: 1-800-365-6832
Fax: 1-800-526-3757
E-Mail: info@flotecwater.com
Web Site: http://www.flotecwater.com
Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 1-800-365-6832
English
Pages 2-12
. . . . . . . . . . . . .
PRINTED IN U.S.A.
®
Series FP4200
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l'utilisation,
l'installation ou l'entretien,
Composer le 1 (800) 365-6832
Français
. . . . . . . . . .
OWNER'S MANUAL
Convertible Deep Well Jet Pumps
NOTICE D'UTILISATION
Pompe à éjecteur transformables
pour puits profonds
MANUAL DEL USUARIO
Bombas Convertibles tipo "Jet"
para Pozos Profundos
2760 0197
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español
Pages 13-24
Paginas 25-36
. . . . . . . . . .
FP411 (Rev. 4/15/03)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FP4200 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Flotec FP4200 Series

  • Page 1 OWNER’S MANUAL Convertible Deep Well Jet Pumps ® NOTICE D’UTILISATION P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Pompe à éjecteur transformables Fax: 1-800-526-3757 pour puits profonds E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com MANUAL DEL USUARIO Bombas Convertibles tipo “Jet” para Pozos Profundos 2760 0197 Series FP4200 Installation/Fonctionnement/Pièces...
  • Page 2: General Safety

    Ground pump before Follow wiring instruc- connecting to power tions in this manual supply. Disconnect power when connecting motor to before working on pump, motor or tank. power lines. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 3: Table Of Contents

    Requests for service under this warranty shall be made by returning the defec- Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it tive product to the Retail outlet or to FLOTEC as soon as possible after the dis- shall be replaced, subject to the terms set forth below.
  • Page 4: Replacing An Existing Pump

    If the pump does not perform properly, Suction Pipe Port to Pump Suction we recommend that you install Flotec ejector kit FP4800. 2755 0197 Step 3. Install the pump in the system. Make sure that all pipe joints in the Figure 1: Drive and Suction Functions suction pipe are air-tight as well as water tight.
  • Page 5: New Shallow Well Installation

    Support the pipe so that there are no dips or sags in the pipe, so it doesn’t Strainer 5-10' Figure 5: Cased Well Installation 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 6: Installation For Surface Water

    You have just completed the plumbing for your new shallow well jet Screen Scale pump. Please go to Page 8 for discharge pipe and tank connections. 5 to 10' 2749 0197 Figure 7: Surface Water Installation 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 7: New Deep Well Installation

    You have just completed the plumbing for your new single pipe deep well jet pump. Please go to Page 8 for discharge pipe and tank connections. Scale Nozzle Ejector 2752 0197 Figure 9: 2” (Single Pipe) Deep Well 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 8: Discharge Pipe And Pressure Tank Connections

    115/230 9.4/4.7 15/15 14/14 (2/2) 14/14 (2/2) 12/14 (3/2) 10/14 (5/2) 8/14 (7/2) 8/12 (7/3) 115/230 12.2/6.1 20/15 14/14 (2/2) 14/14 (2/2) 10/14 (5/2) 8/14 (7/2) 6/14 (9/2) 6/12 (9/3) 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 9: Electrical

    You have just completed the wiring for your pump. all local codes and ordinances that apply. Consult your local building inspector for code information. Please go to Page 10 or 11 for startup preparations. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 10: Preparing To Start The Pump - Deep Well

    Stabilizes 2754 0197 Step 2. Replace all fill plugs. Leave the control valve open (in a shallow well installation, the control valve always stays open). Figure 15: Set Control Valve 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
  • Page 11: Repair Parts

    Preparing to Start the Pump Step 3. Power on! Start the pump. The pump should pump water in two or three minutes. Step 4. If you don’t have water after 2 or 3 minutes, stop the pump and remove the fill plugs. Refill the pump and piping. You may have to Open control valve as far as possible repeat this two or three times in order to get all the trapped air out...
  • Page 12: Troubleshooting

    Well is gaseous Consult factory about installing a sleeve in the well Intermittent over-pumping of well. Lower foot valve if possible, otherwise restrict pump discharge (Water drawn down below foot valve.) 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...