Page 1
OWNER’S MANUAL Convertible Deep Well Jet Pumps ® NOTICE D’UTILISATION P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Pompe à éjecteur transformables Fax: 1-800-526-3757 pour puits profonds E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com MANUAL DEL USUARIO Bombas Convertibles tipo “Jet” para Pozos Profundos 2760 0197 Series FP4200 Installation/Fonctionnement/Pièces...
Ground pump before Follow wiring instruc- connecting to power tions in this manual supply. Disconnect power when connecting motor to before working on pump, motor or tank. power lines. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Requests for service under this warranty shall be made by returning the defec- Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it tive product to the Retail outlet or to FLOTEC as soon as possible after the dis- shall be replaced, subject to the terms set forth below.
If the pump does not perform properly, Suction Pipe Port to Pump Suction we recommend that you install Flotec ejector kit FP4800. 2755 0197 Step 3. Install the pump in the system. Make sure that all pipe joints in the Figure 1: Drive and Suction Functions suction pipe are air-tight as well as water tight.
Support the pipe so that there are no dips or sags in the pipe, so it doesn’t Strainer 5-10' Figure 5: Cased Well Installation 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
You have just completed the plumbing for your new shallow well jet Screen Scale pump. Please go to Page 8 for discharge pipe and tank connections. 5 to 10' 2749 0197 Figure 7: Surface Water Installation 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
You have just completed the plumbing for your new single pipe deep well jet pump. Please go to Page 8 for discharge pipe and tank connections. Scale Nozzle Ejector 2752 0197 Figure 9: 2” (Single Pipe) Deep Well 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
You have just completed the wiring for your pump. all local codes and ordinances that apply. Consult your local building inspector for code information. Please go to Page 10 or 11 for startup preparations. 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Stabilizes 2754 0197 Step 2. Replace all fill plugs. Leave the control valve open (in a shallow well installation, the control valve always stays open). Figure 15: Set Control Valve 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Preparing to Start the Pump Step 3. Power on! Start the pump. The pump should pump water in two or three minutes. Step 4. If you don’t have water after 2 or 3 minutes, stop the pump and remove the fill plugs. Refill the pump and piping. You may have to Open control valve as far as possible repeat this two or three times in order to get all the trapped air out...
Well is gaseous Consult factory about installing a sleeve in the well Intermittent over-pumping of well. Lower foot valve if possible, otherwise restrict pump discharge (Water drawn down below foot valve.) 1-800-365-6832 For parts or assistance, call Flotec Customer Service at...
Need help?
Do you have a question about the FP4200 Series and is the answer not in the manual?