14-Slot AdvancedTCA Shelf
11596-100/-101/-102/-103

4.9 Shelf Manager Replacement

Danger of electrostatic discharge!
Static electricity can harm delicate components inside the Shelf. You must
wear an ESD wrist strap before exchanging any part or electric component!
Figure 22: Shelf Manager
1
Fixing Screw
2
Lever
3
Status LED (red)
Remove:
1 Unscrew the fixing screw (1).
2 Move the lever (2) to position (B) until the blue Hot Swap LED (5) starts
blinking.
3 When the Hot Swap LED is solid blue, move the lever (2) to position (C) and
pull out the Shelf Manager.
Install:
1 Insert the Shelf Manager into the guides and push it completely into the
Shelf. The lever (2) must be in position (C).
2 Close the lever (2) to position (A) and tighten the fixing screw (1).
3 The Shelf Manager is booting now. After aprox. one Minute the green Status
LED (4) indicates that the Shelf Manager is functional.
The Status LED of the active Shelf Manager is solid green, the Status LED of
the backup Shelf Manager is blinking.
www.a-tca.com / www.schroff.biz
4
Status LED (green)
5
Hot Swap LED (blue)