Basic Cli Commands - Pentair Schroff AdvancedTCA 11596-100 Service Manual

Shelf, 14-slot
Table of Contents

Advertisement

14-Slot AdvancedTCA Shelf
11596-100/-101/-102/-103

4.1.2 Basic CLI Commands

Service personnel can read system information, FRU information and sensor
data with the following basic commands. For a full list of all CLI commands refer
to the Firmware User Manual.
• Change IP address of the primary Shelf Manager:
Value represents the IP address in dotted decimal notation.
• Display the Shelf Managers firmware version:
Info: To get a complete list of all information just type in "version".
• List all IPM Controllers in a Shelf:
• List all boards in the Shelf:
• List all sensors on a board:
• List only sensors which are outside of established thresholds:
• Get data (value) from a sensor on a board:
• Display the FRU information in a board:
• Change the speed for a Fan Tray:
Info: The value for the speed is from 0 to 4.
• Display the contents of the System Event Log (SEL):
• Clear the System Event Log (SEL):
www.a-tca.com / www.schroff.biz
clia setlanconfig channel ip value
clia setlanconfig 1 ip 192.168.0.2
clia version
clia ipmc
clia board
clia sensor IPMI-address
clia sensor -t
clia sensordata IPMI-address sensor-number
clia fruinfo IPMI-address FRU-id
clia setfanlevel IPMI-address Fru-id speed
clia sel
clia sel clear