11596-100/-101/-102/-103

4.6 Shelf Alarm Display (SAD) Replacement

Danger of electrostatic discharge!
Static electricity can harm delicate components inside the Shelf. You must
wear an ESD wrist strap before exchanging any part or electric component!
Figure 19: Shelf Alarm Display (SAD)
1
Shelf Alarm Display
2
Fixing Screws
Remove:
1 Unscrew both fixing screws (2).
2 Pull out Shelf Alarm Display (1).
Note: Pull at both fixing screws (2).
Install:
1 Insert the guides (3) of the Shelf Alarm Display into the slots (4) of the
Horizontal board.
2 Insert the Shelf Alarm Display.
3 Tighten both fixing screws (2).
Torque: 0.67 Nm (6 in.-lb.)
www.a-tca.com / www.schroff.biz
3
Guides
4
Slots