Installation The Power Connection Cables - Pentair Schroff AdvancedTCA 11596-100 Service Manual

Shelf, 14-slot
Table of Contents

Advertisement

14-Slot AdvancedTCA Shelf
11596-100/-101/-102/-103
Figure 11: PEM components
5
Terminal Cover
Table 3: PEM Input Power Terminal
Terminal -48/-60 VDC#

3.8 Installation the power connection cables

1 Remove the terminal cover (5).
2 Ensure that the power supply is turned off.
3 Connect the power cables to the power terminal as shown in Fig.9
Torque for Bolts 8-32 UNC: 1.4 Nm (12.5 in.-lb.)
Note: Verify the correct polarity of the -48 VDC and the RTN cables!
4 Fix the cables with cable ties.
5 Install the terminal cover (5).
www.a-tca.com / www.schroff.biz
Designation
1
Power Input Feed 1
2
Power Input Feed 2
3
Power Input Feed 3
4
Power Input Feed 4
Terminal RTN#
1
2
3
4
18
Shelf Installation
12706901
Designation
Return Voltage Feed 1
Return Voltage Feed 2
Return Voltage Feed 3
Return Voltage Feed 4
R1.1, July 23, 2008