ferroamp EnergyHub system Commissioning Manual

Hide thumbs Also See for EnergyHub system:

Advertisement

Available languages

Available languages

Quick Links

Commissioning
guide
EnergyHub system
Rev A01

Advertisement

loading

Summary of Contents for ferroamp EnergyHub system

  • Page 1 Commissioning guide EnergyHub system Rev A01...
  • Page 3: Revision History

    EnergyHub + SSO + Battery ......................................9 Revision history Date Revision 2020.11.03 A01–English & Swedish PN: PD01295, Copyright Ferroamp Elektronik AB 2020. Document subject to change without prior notice. Verify that you have the latest version of this manual on our website. www.ferroamp.com/downloads...
  • Page 4 är satt till ”Measuring” innan du går vidare till steg 9. www.ferroamp.com/downloads, Installer verification.pdf). Om inte fortsätt med steg 8. Starta EnergyHub: EnergyHub Wall & Single XL: Slå på arbetsbrytaren som kopplar ifrån ditt system från byggnadens AC- nät.
  • Page 5 För mer information om de olika strömtransformatorerna kan du läsa Current Sensor Overview.pdf tillgänglig på www.ferroamp.com/downloads 16. Konfigurationen tar upp till 3 minuter per EnergyHub-modul, 11. För att kunna ändra CT kvoten, tryck på omvandlingstalet. under tiden visas ett framstegsfält. När kalibreringen är klar Följande vy dyker då...
  • Page 6 över SSO installationen som beskriver var de knapparna, för att ställa in tröskelvärde för fasbalanseringen. olika SSO:erna är placerade utefter deras unika serienummer som Ferroamp rekommenderar att du väljer ett värde som är märkt på sidan av varje SSO. motsvarar 75% av din huvudsäkring.
  • Page 7 585–780 VDC. Om polaritet och spänning är korrekt kan du slå på DC- brytarna. Registrera systemet i Ferroamp EnergyCloud genom att följa instruktionerna i EnergyCloud registration-häftet. För att aktivera och konfigurera ditt batteri måste du kontakta När samtliga SSO:er har detekterats, gå...
  • Page 8 English. Introduction This booklet will take you through the commissioning process for your EnergyHub system. Go to the section that best describes your system topology and follow the instructions. Read through all the instructions before proceeding with the commissioning.
  • Page 9 For more information regarding the current transformers read the Current Sensors Overview.pdf available at 16. The configuration takes up to 3 minutes per EnergyHub www.ferroamp.com/downloads module, during the configuration a progress bar is shown. When calibration is completed a textbox with the text 11.
  • Page 10 Sign the document before proceeding. 25. Commissioning is now completed! To register the system in the Ferroamp EnergyCloud follow the instructions in the EnergyCloud registration booklet. NOTE! A successful CT-configuration is necessary for the system to function properly.
  • Page 11 If the polarity and voltages are correct go ahead and turn on the DC breakers. Register the system in the Ferroamp EnergyCloud, follow the instructions in the EnergyCloud registration booklet. When all SSOs have been detected, go ahead and activate PV To activate and configure your battery you must contact production and ACE functionality.
  • Page 12 Electricity. Reinvented.