www.raider.bg
parameter
Rated flow
Max. flow rate
Opening temperature thermal valve
Inlet connection
Outlet connection
Suction height
Length x width x height
Typical operating weight
Intended use
This appliance is designed for cleaning:
machines, vehicles, buildings, tools, façades, terraces, garden equipment, etc.
– for low-pressure cleaning with a cleaning agent (e.g. cleaning machines, vehicles, buildings, tools),
– for high-pressure cleaning without a cleaning agent (e.g. cleaning façades, terraces, garden
equipment).
Self-priming when using alternative water sources
This appliance is self-priming and allows the suction of water from containers and natural sources.
It is IMPORTANT that the filter on the water inlet is cleaned and in place, and that only clean water is
sucked in. Any other use that is not expressly permitted in these operating instructions may damage the
appliance and represents a serious risk for the user.
Please make sure that you pay attention to the restrictions in the safety instructions. Pay attention to
the national regulations which may restrict the use of the machine. Any other uses of or modifications to
the machine are deemed to be improper usage and may result in serious physical injury.
Not intended for commercial use.
DANGER!
► Risk of injury! When using at petrol filling stations or other danger areas, comply with all
corresponding safety regulations.
NOTE
► Waster water that is contaminated with oil should not be released into the soil, open water or down
drains. Therefore, only wash engines and vehicle underbodies at suitable sites that have oil separators.
CAUTION! Water quality requirements:
■ Only clean water may be used as a high-pressure medium. Contamination can lead to premature
wear or residues in the appliance. If recycling water is used, the following thresholds may not be
exceeded.
pH value
Electrical conductivity*
Settleable solids**
Filterable substances***
Hydrocarbons
unit
l/min
l/min
°C
m
Dimensions and weight
mm
kg
6.5...9.5
Conductivity Fresh water +1200 μS/cm
< 0.5 mg/l
< 50 mg/l
< 20 mg/l
value
8.3
10
>45
G3/4"
M22 x 1.5
1
645 mm × 570 mm × 970 mm
approx. 30