Bryant PLUS 90X 353AAV Product Data page 5

4--way multipoise condensing gas furnace input rates: 40,000 only
Table of Contents

Advertisement

BRYANT ACCESSORIES*
GAS CONVERSION KIT ---
NATURAL TO PROPANE
GAS CONVERSION KIT ---
PROPANE TO NATURAL
MANUFACTURED (MOBILE)
HOME KIT
DOWNFLOW BASE
(For Combustible Floors)}
VENT TERMINATION KIT
(Bracket Only for 2 Pipes)
CONCENTRIC TERMINATION
KIT (Single Exit)
CONDENSATE FREEZE
PROTECTION KIT
CONDENSATE NEUTRALIZER
KIT (Obtained thru RCD)
ELECTRONIC AIR CLEANER
(EAC)
AIR PURIFIER
MECHANICAL AIR CLEANER
HUMIDIFIER
HEAT RECOVERY VENTILATOR
ENERGY RECOVERY
VENTILATOR
UV LIGHTS
VENT/EXHAUST PIPE
EXTERNAL TRAP KIT
DOOR GASKET KIT
UNFRAMED FILTER,
PERMANENT WASHABLE 3/4"
(19mm)
16 x 25 (406 x 635 mm)
UNFRAMED FILTER,
PERMANENT WASHABLE 3/4"
(19mm)
16 x 25 (508 x 635 mm)
UNFRAMED FILTER,
PERMANENT WASHABLE 3/4"
(19mm)
16 x 25 (610 x 635 mm)
THERMOSTAT ---
NON--- PROGRAMMABLE
THERMOSTAT ---
PROGRAMMABLE
ZONING CONTROL
*Factory---authorized and field---installed. Gas conversion kits are CSA (A.G.A./C.G.A.) recognized
Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant cased coil is used.
*Model HP and 2S thermostat must be field converted to air conditioner operation.
l
{Thermidistatt Contro
control can be configured for multiple use and staging. It must be configured for each specific application.
}Dual Fuel thermostat is used with furnace and heat pump application.
ACCESSORIES
2 --- IN. --- KGAVT0101BRA
2 --- IN. --- KGAVT0701CVT
Models GAPAAXBB1625, GAPAAXBB2025
For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover --- T6 --- NAC, T2 --- NAC
For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover --- T6 --- NHP--- T2 --- NHP*
For use with 2 --- speed Air Conditioner --- deg. F/C, Auto Changeover --- T6 --- NRH*
For use with multi--- use / stage configurations --- deg. F/C, Auto Changeover/Temperature and
Humidity Control --- T6 --- PRH
{
For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover, 7 --- Day Programmable ---
T6 --- PAC
For use with 1 --- speed Air Conditioner --- deg. F/C, Auto Changeover, 7 --- Day Programmable ---
T6 --- PHP*
For use with 2 --- speed Air Conditioner --- deg. F/C, Auto Changeover, 7 --- Day Programmable ---
T6 --- PRH*
For use with 1 --- speed Air Conditioner --- deg. F/C, 5 --- 2 Day Programmable --- T2 --- PAC
For use with multi--- stage applications --- deg. F/C, Auto Changeover, 7 --- Day Programmable ---
T6 --- PHP
}
For multi--- use / stage configurations --- deg. F/C, Auto Changeover, 7 --- Day Programmable/
Temperature and Humidity Control --- T6 --- PRH
Comfort Series Three--- Zone Zone Kit --- ZONEBB3ZAC01, ZONEBB3ZHP01
2 --- Performance Series Zoning/Temperature and Humidity Control --- ZONEBB2KIT01 --- B
4 --- Performance Series Zoning/Temperature and Humidity Control --- ZONEBB4KIT01 --- B
8 --- Performance Series Zoning/Temperature and Humidity Control --- ZONEBB8KIT01 --- B
KGANP4601ALL
KGANP3901ALL
KGAMH0301KIT
KGASB0301ALL
3 --- IN. --- KGAVT0201BRA
3 --- IN. --- KGAVT0801CVT
KGAHT01010CFP
P908 --- 0001
Model EACB
Models EZXCAB, FILCAB
Model HUM
Model HRV
Model ERV
Model UVL
KGAET0106ETK
KGBAC0110DGK
KGAWF1301UFR
KGAWF1401UFR
KGAWF1501UFR
{
5

Advertisement

Table of Contents
loading

Table of Contents